MUNCY, PA —
OSHA Inspection: BEST LINE LEASING INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BEST LINE LEASING INC in 25 LEGION ROAD, MUNCY, PA 17756 (NAICS 423440). OSHA activity number 346535727.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BEST LINE LEASING INC
- Site address
- 25 LEGION ROAD
- City
- MUNCY
- State
- PA
- ZIP
- 17756
- Mailing
- 25 LEGION ROAD, MUNCY, PA 17756
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423440
- Employees
- 40
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.303 G01
- Issued
- Apr 3, 2023
- Penalty
- Initial $5,645 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Main Shop Garage, Southern Interior Wall- On or about March 1, 2023, employees working in the back storage room were exposed to an electric hazard due to objects and equipment being placed in front of the pump panel. Corrected During Inspection
Recent events (2)
- — I (S) $3150
- — Z (S) $5645
1910.303 G02 I
- Issued
- Apr 3, 2023
- Penalty
- Initial $3,387 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) Main Shop Garage, Southern Exterior Wall- On or about March 1, 2023, employees working along the southern exterior wall of the main shop garage were exposed to an electric hazard due to the conduit being broken and the electrical wires were unprotected. Corrected During Inspection
Recent events (2)
- — I (S) $1700
- — Z (S) $3387
1910.334 A02 II
- Issued
- Apr 3, 2023
- Penalty
- Initial $5,645 · Current $3,150 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: a) Southern Exterior Wall, Main Shop Garage- On or about March 1, 2023, employees working along the Southern exterior wall of the main shop garage were exposed to an electric hazard due to extension cords being damaged. Corrected During Inspection
Recent events (2)
- — I (S) $3150
- — Z (S) $5645
More inspections in this industry (NAICS 423440)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346535727.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.