Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CHIPOTLE MEXICAN GRILL

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHIPOTLE MEXICAN GRILL in 359 MAINE MALL ROAD, SOUTH PORTLAND, ME 04106 (NAICS 722513). OSHA activity number 346542574.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Chipotle Mexican Grill — free Get an email when a new federal OSHA severe-injury report for Chipotle Mexican Grill is published. One employer, no account, unsubscribe in one click.
Site address
359 MAINE MALL ROAD
City
SOUTH PORTLAND
State
ME
ZIP
04106
Mailing
610 NEWPORT CENTER DRIVE SUITE 1400, NEWPORT BEACH, CA 92660
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722513
Employees
3
Ownership type
A

5 citations on file for this inspection.

1910.303 G01 II

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
May 24, 2023
Penalty
Initial $7,366 · Current $0 Reduced
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  Closet in the dining area - Multiple bins of supplies and clothes were stored in front of two electrical panels which obstructed prompt access to the panels.
Recent events (3)
  • — D (S) $0
  • — C (S) $7366
  • — Z (S) $7366

1910.304 G05

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
May 24, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  Front line / Counter - The grounding path of the cold storage refrigerator was not continuous.  The ground pin was missing from the plug connected to the cold storage refrigerator and lodged into the electric receptacle.
Recent events (3)
  • — D (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.334 A02 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
May 24, 2023
Abate by
Aug 3, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).  Front line / counter - The portable cold storage refrigerator on the front line was not visually inspected before each shift for defects. Specifically, the plug which was missing its ground pin. The ground pin was broken off inside the electrical receptacle.
Recent events (3)
  • — D (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.157 C01

Deleted Other-than-serious 1 instance 3 exposed
Issued
May 24, 2023
Abate by
Jun 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible.  Rear exit door - A fire extinguisher was not mounted in its designated location by the exit door. The fire extinguisher was sitting on the floor in the back of the kitchen area.
Recent events (3)
  • — D (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.157 E02

Deleted Other-than-serious 1 instance 3 exposed
Issued
May 24, 2023
Abate by
Jun 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly.  Establishment - The employer did not conduct a monthly fire extinguisher inspection on the fire extinguisher that was in the back of the kitchen area.
Recent events (3)
  • — D (O) $0
  • — C (O) $0
  • — Z (O) $0

View Chipotle Mexican Grill's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346542574.