PHILADELPHIA, PA —
OSHA Inspection: AGAPE BUILDERS LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of AGAPE BUILDERS LLC in 7145 KEYSTONE ST., PHILADELPHIA, PA 19135 (NAICS 236116). OSHA activity number 346543770.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AGAPE BUILDERS LLC
- Site address
- 7145 KEYSTONE ST.
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19135
- Mailing
- 826 HARRISON AVE., KEARNY, NJ 07032
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.502 B01
- Issued
- Aug 18, 2023
- Abate by
- Sep 7, 2023
- Penalty
- Initial $4,465 · Current $4,465
General-duty citation text
29 CFR 1926.502(b)(1):The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: a)Jobsite: 7145 Keystone St., Philadelphia, PA 19135 - The employer installed the top rail of the elevator shaft approximately 60 inches from the walking working level, exposing employees installing drywall in close proximity to the elevator shaft to fall hazards of approximately 40 feet to the ground. Condition noted on/about February 23, 2023
Recent events (1)
- — Z (S) $4465
1926.502 B02 I
- Issued
- Aug 18, 2023
- Abate by
- Sep 7, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(2)(i): Midrails, when used, shall be installed at a height midway between the top edge of the guardrail system and the walking/working level. a) Jobsite: 7145 Keystone St., Philadelphia, PA 19135 - The employer installed the mid rail of the elevator shaft approximately 19 inches from the walking working level, and not at the midway point of approximately 30 inches between the top rail and working level, exposing employees installing drywall in close proximity to the elevator shaft to fall hazards of approximately 40 feet to the ground. Condition noted on/about February 23, 2023