Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WILLIAM BRAY CABINETMAKER, LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of WILLIAM BRAY CABINETMAKER, LLC in 23 WITCHTROT RD, YORK, ME 03909 (NAICS 337110). OSHA activity number 346547037.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch William Bray Cabinetmaker, LLC — free Get an email when a new federal OSHA severe-injury report for William Bray Cabinetmaker, LLC is published. One employer, no account, unsubscribe in one click.
Site address
23 WITCHTROT RD
City
YORK
State
ME
ZIP
03909
Mailing
PO BOX 441, KITTERY, ME 03904
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
5
Ownership type
A

4 citations on file for this inspection.

1910.178 Q07

Serious Gravity 5 1 instance 6 exposed
Issued
Apr 11, 2023
Penalty
Initial $3,683 · Current $1,842 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  23 Witchtrot Rd, York, Maine - The employer did not ensure fork lift operators inspected the Hyster 60 fork truck prior to use to ensure safe operating conditions.
Recent events (2)
  • — I (S) $1841.5
  • — Z (S) $3683

1910.303 G01 II

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 11, 2023
Penalty
Initial $2,210 · Current $1,105 Reduced
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:(a) (LOCATION) (IDENTIFY EQUIPMENT AND CONDITION(S)) (STATE HAZARD(S) TO EMPLOYEE(S))   23 Witchtrot Rd, York, ME - The employer did not ensure electrical panels, operating under 600 volts in the back room of the new building, were kept free and unobstructed by storing spare parts and a wooden box in front of the panel.
Recent events (2)
  • — I (S) $1105
  • — Z (S) $2210

1910.157 C01

Other-than-serious 1 instance 6 exposed
Issued
Apr 11, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  23 Witchtrot Rd, York, ME - The employer did not mount and identify the portable fire extinguisher located on the floor near the doorway separating the two large areas in the new building.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 6 exposed
Issued
Apr 11, 2023
Abate by
May 5, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  23 Witchtrot Rd, York, ME - The employer did not ensure the portable fire extinguisher located in the new shop area was inspected at least monthly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View William Bray Cabinetmaker, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346547037.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.