Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LANDRY?S CRAB SHACK, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LANDRY?S CRAB SHACK, LLC in 215 KIPP AVE., KEMAH, TX 77565 (NAICS 713110). OSHA activity number 346547946.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Landry?S Crab Shack, LLC — free Get an email when a new federal OSHA severe-injury report for Landry?S Crab Shack, LLC is published. One employer, no account, unsubscribe in one click.
Site address
215 KIPP AVE.
City
KEMAH
State
TX
ZIP
77565
Mailing
ATTN: COLIN BEAR 1510 WEST LOOP SOUTH, HOUSTON, TX 77027
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713110
Employees
6
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 30, 2023
Abate by
Sep 19, 2023
Penalty
Initial $13,394 · Current $10,715 Reduced
29 CFR  1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  a) At the amusement park, the energy control procedures used by employees when inspecting the Flare, 22M Giant Loop roller coaster did not clearly and specifically outline the steps for isolating the electric and kinetic energy sources.
Recent events (2)
  • — I (S) $10715.2
  • — Z (S) $13394

1910.147 D03

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 30, 2023
Penalty
Initial $15,625 · Current $12,500 Reduced
29 CFR  1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  a) At the amusement park, where the electric and kinetic energy sources were not de-energized after an employee repositioned the 22M Giant Loop roller coaster during an inspection.
Recent events (2)
  • — I (S) $12500
  • — Z (S) $15625

1910.147 F01 V

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Aug 30, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(f)(1)(v): All systems were not de-energized and energy control measures reapplied in accordance with paragraph (d) of this section to continue the servicing and/or maintenance:  a) At the amusement park, where energy control procedures were not reapplied after the 22M Giant Loop roller coaster was repositioned during an inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 30, 2023
Penalty
Initial $11,162 · Current $0 Reduced
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  a) At the amusement park, where a locking device was not used on the Flare, 22M Giant Loop when an inertia ring pin was used to control the kinetic energy for employees performing inspection tasks on the roller coaster.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11162

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 30, 2023
Penalty
Initial $13,394 · Current $10,715 Reduced
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) Under the 22M Giant Loop roller coaster, where a gap in an enclosure box was not covered, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $10715.2
  • — Z (S) $13394

1910.305 G01 IV A

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 30, 2023
Penalty
Initial $8,929 · Current $7,143 Reduced
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Under the 22M Giant Loop roller coaster, where an extension cord was permanently used to supply power to a Husky, C271H, Portable Vertical Electric Air Compressor.
Recent events (2)
  • — I (S) $7143.2
  • — Z (S) $8929

1910.147 C06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 30, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) At the amusement park, where energy controls procedures were not conducted annually for employees inspecting roller coasters such as, but not limited to, the Flare, 22M Giant Loop.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346547946.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.