Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPT OF VETERANS AFFAIRS - NATIONAL CEMETERY ADMINISTRATION - SAN JOAQU?N VALLEY NATIONAL CEMETERY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPT OF VETERANS AFFAIRS - NATIONAL CEMETERY ADMINISTRATION - SAN JOAQU?N VALLEY NATIONAL CEMETERY in 32053 WEST MCCABE ROAD, SANTA NELLA, CA 95322 (NAICS 812220). OSHA activity number 346549074.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Dept of Veterans Affairs - National Cemetery Administration - SAN Joaqu?N Valley National Cemetery — free Get an email when a new federal OSHA severe-injury report for U.S. Dept of Veterans Affairs - National Cemetery Administration - SAN Joaqu?N Valley National Cemetery is published. One employer, no account, unsubscribe in one click.
Site address
32053 WEST MCCABE ROAD
City
SANTA NELLA
State
CA
ZIP
95322
Mailing
32053 WEST MCCABE ROAD, SANTA NELLA, CA 95322
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812220
Employees
17
Ownership type
D

5 citations on file for this inspection.

1910.184 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 24, 2023
Abate by
Apr 19, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.184(c)(2): Slings were shortened with knots or bolts or other makeshift devices.  Located in section 21 of the cemetery, a chain sling was wrapped around a mini-excavator tamper attachment and shortened with a makeshift device (a hook). Employees are exposed to material handling hazards including dropped loads and potential injuries such as broken bones or crushing.
Recent events (1)
  • — Z (S) $0

1910.184 C07

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 24, 2023
Abate by
Apr 19, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.184(c)(7): Slings were not padded or protected from sharp edges of their loads.  Located in section 21, the chain sling used to lift grave covers into place was not protected from sharp edges of the excavator tamper. Employees are exposed to material handling and dropped load hazards that could result in broken bones or crushing injuries.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(1): Types of guarding. One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  1). Located in the mechanic's shop, a Rockwell Manufacturing Co. drill press was not guarded at the point of operation.   2). Located in the mechanic's shop, a yellow Enerpac hydraulic press was not guarded at the point of operation.   Employees are exposed to struck-by flying objects and caught-in hazards that could result in lacerations, eye injury, or amputations.
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 1 2 instances 1 exposed
Issued
Mar 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.212(b): Machines designed for fixed locations were not securely anchored to prevent walking or moving:  1). Located in the mechanic's shop next to the exit door, the yellow Enerpac hydraulic press was not securely anchored to the floor to prevent moving.  2). Located in the mechanic's shop next to the black cabinet, the Rockwell drill press was not securely anchored to the work bench to prevent walking or moving.   Employees are exposed to machine tipover hazards that could result in crushing or lacerations.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 24, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment.  Located in the mechanic's shop, a 120/208 volt safety shutoff switch was obstructed by a table and other objects. The shutoff switch powered electrical outlets including one connected to a welding machine.  Employees are exposed to an electrical hazard that can lead to injuries such as smoke inhalation or burns.
Recent events (1)
  • — Z (S) $0

View U.S. Dept of Veterans Affairs - National Cemetery Administration - SAN Joaqu?N Valley National Cemetery's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346549074.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.