NYACK, NY —
OSHA Inspection: A & B SITE SERVICES, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of A & B SITE SERVICES, LLC in 9 VINE ST, NYACK, NY 10960 (NAICS 238170). OSHA activity number 346549918.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A & B SITE SERVICES, LLC
- Site address
- 9 VINE ST
- City
- NYACK
- State
- NY
- ZIP
- 10960
- Mailing
- 9 VINE ST, NYACK, NY 10960
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 E01
- Issued
- Apr 11, 2023
- Abate by
- Apr 21, 2023
- Penalty
- Initial $4,688 · Current $3,267 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a) 9 Vine St. Nyack NY (Exterior Single Family Home): Employees engaged in siding work, were climbing the cross braces of a tubular three frame scaffold, to access the working platform. The employer did not ensure that employees accessing a tubular frame scaffold were provided with adequate means of access, on or about 3/7/23.
Recent events (2)
- — I (S) $3266.67
- — Z (S) $4688
1926.451 G01
- Issued
- Apr 11, 2023
- Abate by
- Apr 17, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) 9 Vine St. Nyack, NY (Exterior East Side of Single Family Home): Employees engaged in siding work, were working from a tubular three frame scaffold, and were exposed to a fall hazard of over 20 feet above the lower level, without a personal fall arrest system or other means of fall protection equipment. The employer did not ensure that fall protection was provided for affected employees, while working from a tubular frame scaffold, over 10 feet above the lower level, thus exposing employees to a fall hazard, on or about 3/7/23.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Apr 11, 2023
- Abate by
- Apr 17, 2023
- Penalty
- Initial $4,688 · Current $3,267 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 9 Vine St. Nyack, NY (Exterior East Side of Single Family Home): Employees engaged in siding work were exposed to a fall hazard over 15 feet above the lower surface, without a personal fall arrest system or other means of fall protection. The employer did not ensure that personal fall arrest system or other means of fall protection was provided for affected employees working above 15 feet above the lower surface, thus exposing employees to a fall hazard, on or about 3/7/23.
Recent events (2)
- — I (S) $3266.67
- — Z (S) $4688
1926.1053 B01
- Issued
- Apr 11, 2023
- Abate by
- Apr 21, 2023
- Penalty
- Initial $4,688 · Current $3,267 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 9 Vine Street, Nyack, NY (Exterior East Side of Family Home): Employees engaged in siding work were using an aluminum extension ladder that did not extend three feet above the roof's upper landing. The employer did not ensure that an aluminum extension ladder extended three feet above the roof's upper landing, on or about 3/7/23.
Recent events (2)
- — I (S) $3266.66
- — Z (S) $4688
More inspections in this industry (NAICS 238170)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346549918.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.