GAINESVILLE, GA —
OSHA Inspection: SALVADOR GIRON
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SALVADOR GIRON in 7 QUARRY ST, GAINESVILLE, GA 30501 (NAICS 238160). OSHA activity number 346556848.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SALVADOR GIRON
- Site address
- 7 QUARRY ST
- City
- GAINESVILLE
- State
- GA
- ZIP
- 30501
- Mailing
- 3010 HEATHER STONE WAY, LAWRENCEVILLE, GA 30043
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- Jun 21, 2023
- Penalty
- Initial $2,846 · Current $2,846
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) Institutional structure located at 7 Quarry St. Gainesville, GA 30501, Roofing area: On or about 3/6/2023, and at times prior, the employer exposed employees to fall hazards of approximately 19-feet, 6-inch to the lower ground level, in that adequate fall protection system was not provided to employees engaged in shingle removal activities on an 8/12 pitched roof.
Recent events (1)
- — Z (S) $2846
1926.502 D17
- Issued
- Jun 21, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(17): The attachment point of the body belt was not located in the center of the wearer's back. The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head. a) Institutional structure located at 7 Quarry St. Gainesville, GA 30501, Roofing area: On or about 3/6/2023, and at times prior, the employer exposed employees to potential struck-by hazards, in that the fall protection system provided did not allow the attachment point to be in the center of the wearer's back near shoulder level, while engaged in shingle installation activities.