ARLINGTON HEIGHTS, IL —
OSHA Inspection: MONTES INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MONTES INC. in 4 N HICKORY AVE., ARLINGTON HEIGHTS, IL 60005 (NAICS 238130). OSHA activity number 346556988.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MONTES INC.
- Site address
- 4 N HICKORY AVE.
- City
- ARLINGTON HEIGHTS
- State
- IL
- ZIP
- 60005
- Mailing
- 1617 N LONG AVE., CHICAGO, IL 60639
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 10
- Ownership type
- A
Citations
5 citations on file for this inspection.
1903.19 C01
- Issued
- Aug 10, 2023
- Abate by
- Aug 29, 2023
- Penalty
- Initial $376 · Current $376
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: Montes Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation 1, Item 1, 1926.501(b)(1) Citation 1, Item 2a, 1926.1052(c)(1)(i) Citation 1, Item 2b, 1926.1052(c)(12) Citation 1, Item 3, 1926.1053(b)(1) In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (O) $376
1926.501 B01
- Issued
- May 23, 2023
- Abate by
- May 30, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: The employer did not protect each employee from fall hazards while engaged in framing work approximately five stories above the ground by the use of guardrail system, safety net system, or personal fall arrest system. a) On February 8, 2023, employees engaged in framing work were not protected from fall hazards while working approximately four stories above the ground. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $4688
1926.1052 C01
- Issued
- May 23, 2023
- Abate by
- May 30, 2023
- Penalty
- Initial $3,349 · Current $3,349
General-duty citation text
29 CFR 1926. 1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail. a) On February 8, 2023, in order to access and egress the workspace, employees were utilizing a stairway containing more than four risers and was not equipped with a handrail. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $3349
1926.1052 C12
- Issued
- May 23, 2023
- Abate by
- May 30, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of this part: a) On February 8, 2023, employees were exposed to the hazard of falling while using stairway landing that was not equipped with a guardrail system. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $0
1926.1053 B01
- Issued
- May 23, 2023
- Abate by
- May 30, 2023
- Penalty
- Initial $3,349 · Current $3,349
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On February 8, 2023, a ladder used by employees to gain access to the working surface did not have side rails capable of extending or that extended at least 3 feet above the surface. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $3349
More inspections in this industry (NAICS 238130)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346556988.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.