OSHA Inspection: U.S. ARMY - PICATINNY ARSENAL

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of U.S. ARMY - PICATINNY ARSENAL in RANGE BUILDING #7, PICATINNY ARSENAL, NJ 07806 (NAICS 928110). OSHA activity number 346557895.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Army - Picatinny Arsenal — free Get an email when a new federal OSHA severe-injury report for U.S. Army - Picatinny Arsenal is published. One employer, no account, unsubscribe in one click.
Site address
RANGE BUILDING #7
City
PICATINNY ARSENAL
State
NJ
ZIP
07806
Mailing
RISK MANAGEMENT OFFICE B355N DEVCOM ARMAMENTS CENTER, PICATINNY ARSENAL, NJ 07806
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
6000
Ownership type
D

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 28, 2023
Abate by
Jul 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about:  February 27, 2023 and continuing Location: Range Building #7, PICATINNY ARSENAL, NJ 07806  a) The employer did not ensure that specific Lockout/Tagout procedures were developed, provided, and used for maintenance for employees  performing servicing on equipment that included, but was not limited to an 90-meter range exhaust fan.  Employee engaged on maintenance of exhaust fan suffered amputation to fingers due to machine not being locked out.
Recent events (1)
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 28, 2023
Abate by
Jul 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    On or about:  February 27, 2023 and continuing Location: Range Building #7, PICATINNY ARSENAL, NJ 07806  a) The employer did not ensure that periodic inspections of the Hazardous Energy Control program were completed at least annually. Employees engaged in the service and repair of equipment that included, but not limited to, a 90-meter range exhaust fan were not observed and evaluated on use and effectiveness of LOTO procedures.
Recent events (1)
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 28, 2023
Abate by
Jul 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolate:    On or about:  February 27, 2023 and continuing Location: Range Building #7, PICATINNY ARSENAL, NJ 07806  a) The employer did not ensure that authorized employees received hazardous energy control training.  Employee who performed maintenance and servicing on equipment that included, but was not limited to, a 90-meter range exhaust fan were not provided Lockout/Tagout training that included methods and means needed to isolate electrical and mechanical energy.
Recent events (1)
  • — Z (S) $0

1910.147 C07 I B

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 28, 2023
Abate by
Jul 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:   On or about:  February 27, 2023 and continuing Location: Range Building #7, PICATINNY ARSENAL, NJ 07806  a) The employer did not ensure that affected employees received hazardous energy control training.  Employees performed servicing and maintenance  on equipment that included, but was not limited to, a 90-meter range exhaust fan and were not provided Lockout/Tagout training that included methods and means needed to isolate electrical and mechanical energy.
Recent events (1)
  • — Z (S) $0