MORTON GROVE, IL —
OSHA Inspection: SKO-DIE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SKO-DIE, INC. in 8050 AUSTIN AVE, MORTON GROVE, IL 60053 (NAICS 332119). OSHA activity number 346558596.
Where did this inspection happen?
- Establishment
- SKO-DIE, INC.
- Site address
- 8050 AUSTIN AVE
- City
- MORTON GROVE
- State
- IL
- ZIP
- 60053
- Mailing
- 8050 AUSTIN AVE, MORTON GROVE, IL 60053
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332119
- Employees
- 118
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.219 C02 I
- Issued
- Abate by
- Penalty
- Initial $8539.00 · Current $5977.00 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Notching Room - On March 6, 2023, the employer did not ensure that the the rotating shaft at the end of the flywheels of V&O Presses #38, and #49, was guarded. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $5977.3
- — Z (S) $8539
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means: a) Notching Room - On March 6, 2023, the employer did not ensure that the electrical control box mounted on the Muller-Weingarten Robot Machine, had the cover completely on and effectively closed. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at SKO-DIE, INC.
MORTON GROVE, IL—1999-09-24 00:00:00
SKO-DIE INC.
MORTON GROVE, IL—1986-02-12 00:00:00
SKO-DIE, INC.
Morton Grove, IL—1983-05-04 00:00:00
SKO DIE INC
Morton Grove, IL—1975-05-22 00:00:00
SKO-DIE INC
View SKO-DIE, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332119)
HIALEAH, FL—2026-07-09 00:00:00
HIALEAH METAL SPINNING, INC.
EVANSVILLE, IN—2026-06-09 00:00:00
HOOSIER STAMPING & MFG CORP
LYNDON STATION, WI—2026-05-20 00:00:00
METALWORKS STAMPING CORPORATION
PORTLAND, TN—2026-05-20 00:00:00
PRECISION INDUSTRIES, INC.
CLINTON TOWNSHIP, MI—2026-05-05 00:00:00
SYNERGY PROTOTYPE STAMPING LLC
More inspections in IL
DEERFIELD, IL—2026-07-16 00:00:00
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16 00:00:00
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16 00:00:00
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16 00:00:00
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16 00:00:00
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346558596.