Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: SKO-DIE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SKO-DIE, INC. in 8050 AUSTIN AVE, MORTON GROVE, IL 60053 (NAICS 332119). OSHA activity number 346558596.

Watch Sko-Die, INC. — free Get an email when a new federal OSHA severe-injury report for Sko-Die, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SKO-DIE, INC.
Site address
8050 AUSTIN AVE
City
MORTON GROVE
State
IL
ZIP
60053
Mailing
8050 AUSTIN AVE, MORTON GROVE, IL 60053
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332119
Employees
118
Ownership type
A

2 citations on file for this inspection.

1910.219 C02 I

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $8539.00 · Current $5977.00 Reduced
29 CFR  1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  a) Notching Room - On March 6, 2023,  the employer did not ensure that the the rotating shaft at the end of the flywheels of V&O Presses #38, and #49, was  guarded.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $5977.3
  • — Z (S) $8539

1910.303 G02 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:  a) Notching Room - On March 6, 2023, the employer did not ensure that the electrical control box mounted on the Muller-Weingarten Robot Machine, had the cover completely on and effectively closed.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View SKO-DIE, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346558596.