EARLE, AR —
OSHA Inspection: ISHU, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ISHU, LLC in 531 ARKANSAS 149, EARLE, AR 72331 (NAICS 447110). OSHA activity number 346565153.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ISHU, LLC
- Site address
- 531 ARKANSAS 149
- City
- EARLE
- State
- AR
- ZIP
- 72331
- Mailing
- 111 S 3RD STREET, CABOT, AR 72023
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 447110
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.101 B
- Issued
- Sep 1, 2023
- Abate by
- Sep 28, 2023
- Penalty
- Initial $3,572 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: On or about March 13, 2023 in the backroom, employees were doing retail sales work such as but not limited to stocking, cleaning, or serving customers while working in and around compressed gas (CO2) cylinders. a) An empty cylinder was stored without its protective cap. b) Five cylinders were stored unsecured and unchained near a water heater. c) Empty and charged cylinders were stored unsecured and unchained together.
Recent events (2)
- — I (S) $1000
- — Z (S) $3572
1910.303 B02
- Issued
- Sep 1, 2023
- Abate by
- Sep 28, 2023
- Penalty
- Initial $2,678 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about March 13, 2023 at the front of the store, a neon sign was receiving power from a brown extension cord that was plugged into (daisy chained) a portable power tap (power strip). b) On or about March 13, 2023 employees worked by the cash register and hot food counter where neon signs were plugged into a metal junction box with pre-punched knockouts installed as a pendant .
Recent events (2)
- — I (S) $1000
- — Z (S) $2678
1910.305 B01 II
- Issued
- Sep 1, 2023
- Abate by
- Sep 28, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or about March 13, 2023 employees worked by the cash register and hot food counter where neon signs and other equipment were plugged into a metal junction box with pre-punched knockouts missing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV B
- Issued
- Sep 1, 2023
- Abate by
- Sep 28, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: a) On or about March 13, 2023 employees worked by the cash register and hot food counter where a flexible power cord providing electrical service to neon signs was run through a hole in the ceiling.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 I
- Issued
- Sep 1, 2023
- Abate by
- Sep 28, 2023
- Penalty
- Initial $3,572 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i): The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S1: a) On or about March 13, 2023 in the backroom, the electrical breaker box was obstructed with items such as but not limited to a hand truck, pressure washer, broom, dust mop, and pressurized CO2 gas cylinders.