GLENPOOL, OK —
OSHA Inspection: TULSA STEEL MANUFACTURING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TULSA STEEL MANUFACTURING in 16420 US-75, GLENPOOL, OK 74033 (NAICS 238120). OSHA activity number 346566656.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TULSA STEEL MANUFACTURING
- Site address
- 16420 US-75
- City
- GLENPOOL
- State
- OK
- ZIP
- 74033
- Mailing
- 16420 US-75, GLENPOOL, OK 74033
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 44
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.28 B01 I
- Issued
- Sep 5, 2023
- Penalty
- Initial $4,687 · Current $4,687
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): On or about March 14, 2023, employees were walking and working around unprotected edges and were not in use of fall protection. This exposed the employees to a fall greater than four feet to the lower level below.
Recent events (1)
- — Z (S) $4687
1910.107 C06
- Issued
- Sep 5, 2023
- Penalty
- Initial $6,250 · Current $6,250
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: On or about March 14, 2023, an electrical pedestal shop fan and an electrical cord were being used in the spray area. This exposed employees to fire hazards.
Recent events (1)
- — Z (S) $6250
1910.107 G02
- Issued
- Sep 5, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: On or about March 14, 2023, residue from the spray operation was allowed to accumulate on surfaces. This exposed the employees to fire hazards.
Recent events (1)
- — Z (S) $0
1910.107 G03
- Issued
- Sep 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(3): Residue disposal. Residue scrapings and debris contaminated with residue were not immediately removed from the premises and properly disposed of in approved metal waste cans and were not properly disposed of at least once daily or at the end of each shift. On or about March 14, 2023, in the spray area, contaminated paper towels, cardboard boxes, and other combustible products were not properly disposed of in the spray area. The debris was piled on top of a metal barrel and this exposed the employees to fire hazards.
Recent events (1)
- — Z (S) $0
1910.134 H01
- Issued
- Sep 5, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $6,250 · Current $6,250
General-duty citation text
29 CFR 1910.134(h)(1): Respirators were not cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer: On or about March 14, 2023, employees were in use of half-face respirators that were not cleaned and disinfected. The respirators were covered in dust and this exposed employees to health hazards.
Recent events (1)
- — Z (S) $6250
1910.134 H02 I
- Issued
- Sep 5, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: On or about March 14, 2023, employees were in use of half-face respirators that were stored in open and dirty areas. This exposed the employees to health hazards.
Recent events (1)
- — Z (S) $0
More inspections at Tulsa Steel Manufacturing
View Tulsa Steel Manufacturing's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346566656.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.