Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NOBLE-X, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NOBLE-X, INC. in 1750 RIDGEWAY STREET, HAMMOND, WI 54015 (NAICS 332710). OSHA activity number 346568876.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Noble-X, INC. — free Get an email when a new federal OSHA severe-injury report for Noble-X, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
NOBLE-X, INC.
Site address
1750 RIDGEWAY STREET
City
HAMMOND
State
WI
ZIP
54015
Mailing
465 GRIFFIN BOULEVARD, AMERY, WI 54001
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
40
Ownership type
A

6 citations on file for this inspection.

1910.147 D03

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2023
Abate by
Oct 6, 2023
Penalty
Initial $8,036 · Current $4,822 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  (a) Building No. 1, cutting area; An employee performed service and maintenance tasks, including but not limited to, lubricating, blade changes, and wire wheel replacement on the Cosen model C-420NC horizontal bandsaw, without isolating equipment energy source(s).
Recent events (2)
  • — I (S) $4821.6
  • — Z (S) $8036

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2023
Abate by
Oct 6, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Building No. 1, cutting area; An employee performed service and maintenance tasks, including but not limited to, lubricating, blade changes, and wire wheel replacement on the Cosen model C-420NC horizontal bandsaw, without affixing lockout or tagout device(s) to the equipment's electrical energy source(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 29, 2023
Abate by
Jul 21, 2023
Penalty
Initial $6,026 · Current $3,616 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Building No. 1, Milling Department; An employee who operated the Bridgeport brand model 47888 vertical milling machine was exposed to hazards associated with rotating parts and/or the point of operation due to an unguarded spindle and end-mill.
Recent events (2)
  • — I (S) $3615.6
  • — Z (S) $6026

1910.215 A04

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 29, 2023
Penalty
Initial $10,246 · Current $6,148 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:   (a) Building No. 1, near CNC Lathe 2; The tool rest located on the Jet brand model IBGB-248, 8-inch industrial pedestal grinder, was adjusted approximately seven-sixteenths of an inch from the surface of the abrasive wheel.
Recent events (2)
  • — I (S) $6147.6
  • — Z (S) $10246

1910.215 B09

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 29, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   (a) Building No. 1, near CNC Lathe 2; The tongue guard located on the Jet brand model IBGB-248, 8-inch industrial pedestal grinder, was adjusted approximately one and three-eighths of an inch from the top of the abrasive wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C05 II D

Other-than-serious 1 instance 1 exposed
Issued
Jun 29, 2023
Abate by
Jul 21, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):  (a) Building No. 1; Lockout devices used to control energy isolation sources during service and maintenance activities did not include the identity of the employees who affixed the devices.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346568876.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.