Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE COCA-COLA COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE COCA-COLA COMPANY in 705 MAIN STREET, AUBURNDALE, FL 33823 (NAICS 312111). OSHA activity number 346570245.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Coca-Cola Company — free Get an email when a new federal OSHA severe-injury report for The Coca-Cola Company is published. One employer, no account, unsubscribe in one click.
Site address
705 MAIN STREET
City
AUBURNDALE
State
FL
ZIP
33823
Mailing
705 MAIN STREET, AUBURNDALE, FL 33823
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
312111
Employees
625
Ownership type
A

3 citations on file for this inspection.

1910.119 D03 I B

Serious Gravity 10 6 instances 625 exposed
Issued
Jul 13, 2023
Abate by
Aug 15, 2023
Penalty
Initial $15,625 · Current $15,625
29 CFR 1910.119(d)(3)(i)(B): The employer's piping and instrument diagrams were not accurate and did not represent equipment that was existing and was part of the process.   a) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/23, a ? inch Hansen HGV1 Long Neck Service/Gauge Valve located on piping associated with suction accumulator V-33 and downstream of an 8-inch isolation/stop valve, RL-1, was not depicted on the employer?s piping and instrumentation diagrams.  b) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/23, pressure gauge at a ? inch service/gauge valve on piping associated with suction accumulator V-33 and downstream of an 8-inch isolation/stop valve, RL-1, was not depicted on the employer?s piping and instrumentation diagrams.  c) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/23, valve RL-1/CH-31 was incorrectly field-labeled with respect to piping and instrumentation drawing number V-33A.  d) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/23, five valves at high pressure receiver V23 had illegible valve tags for valves depicted on piping and instrumentation drawing number V-23.  e) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/23, chiller CH-31 and isolation/stop valve RL-1/V-33 were located on the wrong side of the suction accumulator V-33 with respect to the level column on the piping and instrumentation drawing number V-33A.
Recent events (2)
  • — I (S) $15625
  • — Z (S) $15625

1910.119 D03 II

Deleted Serious Gravity 10 6 instances 625 exposed
Issued
Jul 13, 2023
Abate by
Aug 15, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices.   a) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 03/15/2023, the employer exposed employees to inhalation and skin contact hazards associated with a catastrophic release of pressurized liquid anhydrous ammonia, in that, a pressure gauge and its 1/4 inch service/gauge valve on a 25,000 lb. approximate ammonia suction accumulator vessel V-33 was inoperable and not able to be read. Line breaking activities were commencing at/near the gauge location, and contractors involved were unable to get an accurate read of the pressure inside the pipe where line breaking was going to commence.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

1910.119 J04 I

Serious Gravity 10 3 instances 625 exposed
Issued
Jul 13, 2023
Abate by
Aug 15, 2023
Penalty
Initial $15,625 · Current $15,625
29 CFR  1910.119(j)(4)(i): The employer did not perform inspection and tests on process equipment.   a) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/2023, the employer failed to perform inspections and tests on isolation/stop valve RL-1/V-33.  b) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/2023, the employer failed to perform inspections and tests on a Hansen HGV1 Long Neck ?? gauge/service valve which was installed downstream of isolation/stop valve RL-1/V-33 on suction accumulator 33. A Gritty material had accumulated in the gauge/service valve.  c) For engine room number 2-3 at the Coca-Cola Auburndale, FL site, on or about 3/16/2023, the employer failed to perform inspections and tests on a Hansen HGV1 Long Neck ?? gauge/service valve which was installed downstream of isolation/stop valve RL-1/V-33 on suction accumulator 33. The gauge was inoperable and unable to be read.
Recent events (2)
  • — I (S) $15625
  • — Z (S) $15625

View The Coca-Cola Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346570245.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.