SHREWSBURY, MA —
OSHA Inspection: VALMET FLOW CONTROL INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of VALMET FLOW CONTROL INC in 44 BOWDITCH DRIVE, SHREWSBURY, MA 01545 (NAICS 332911). OSHA activity number 346571441.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VALMET FLOW CONTROL INC
- Site address
- 44 BOWDITCH DRIVE
- City
- SHREWSBURY
- State
- MA
- ZIP
- 01545
- Mailing
- 44 BOWDITCH DRIVE, SHREWSBURY, MA 01545
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332911
- Employees
- 300
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C06 I
- Issued
- Jun 14, 2023
- Penalty
- Initial $8,929 · Current $8,929
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. 44 Bowditch Drive, Shrewsbury, MA.: On or about March 15, 2023 and for over one year prior, the employer had not performed a comprehensive periodic inspection of the energy control procedures including, but not limited to the HSEDP-282 Clincher Assembly Station, at least annually, to verify that each procedure was adequate and being used properly by employees. *Abatement Notes: A periodic inspection shall include the following elements: - Appointment of an authorized employee to inspect each unique procedure for inaccuracies during an actual energy control task - A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use - Certification that the periodic inspections have been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections *Abatement notes are intended only to provide clarity regarding existing requirements under the law or agency policies. Abatement notes do not create (or diminish) legal obligations under the Occupational Safety and Health Act
Recent events (2)
- — I (O) $8929
- — Z (S) $8929
More inspections at Valmet Flow Control INC
View Valmet Flow Control INC's full OSHA safety record →
More inspections in this industry (NAICS 332911)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346571441.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.