MCKINNEY, TX —
OSHA Inspection: HISUN MOTORS CORP. U.S.A
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HISUN MOTORS CORP. U.S.A in 301 E. UNIVERSITY DRIVE, MCKINNEY, TX 75069 (NAICS 336112). OSHA activity number 346571540.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HISUN MOTORS CORP. U.S.A
- Site address
- 301 E. UNIVERSITY DRIVE
- City
- MCKINNEY
- State
- TX
- ZIP
- 75069
- Mailing
- 301 E. UNIVERSITY DRIVE, MCKINNEY, TX 75069
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336112
- Employees
- 187
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 26, 2023
- Abate by
- Jul 7, 2023
- Penalty
- Initial $14,063 · Current $7,534 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which was free from recognized hazards of being struck-by and/or crushed-by suspended loads which were causing or likely to cause death or serious physical harm to employees: a) The employer did not remove from service damaged hook. This violation occurred on or about March 21, 2023, and at times prior thereto; when employees operating Yale overhead underhung crane with a broken safety latch at the throat of the hook were exposed to struck-by and/or crushed-by hazards.
Recent events (2)
- — I (S) $7534
- — Z (S) $14063
1910.22 A01
- Issued
- Jun 26, 2023
- Abate by
- Jul 7, 2023
- Penalty
- Initial $10,046 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition: a) On or about March 15, 2023, and at times prior thereto; in the uncrate area, where materials, nut bolts and screws on floor, exposing employees to slip, trip and fall hazards. b) On or about March 21, 2023, and at times prior thereto; in the subassembly area, where extension cords on floor, exposing employees to trip and fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $10046
1910.22 A02
- Issued
- Jun 26, 2023
- Abate by
- Jul 7, 2023
- Penalty
- Initial $10,046 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition. a) On or about March 15, 2023, and at times prior thereto; in the uncrate area, where water was standing in the work area/ passageway, exposing employees to slip and fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $10046
1910.178 L01 I
- Issued
- Jun 26, 2023
- Abate by
- Jul 7, 2023
- Penalty
- Initial $14,063 · Current $7,534 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) This violation occurred on or about March 15, 2023 and at times prior thereto; when employees were operating the forklifts without having formal instruction, practical training and evaluation.
Recent events (2)
- — I (O) $7534
- — Z (S) $14063
1910.184 C01
- Issued
- Jun 26, 2023
- Abate by
- Jul 7, 2023
- Penalty
- Initial $14,063 · Current $7,534 Reduced
General-duty citation text
29 CFR 1910.184(c)(1): Slings that are damaged or defective shall not be used. a) This violation occurred on or about March 21, 2023, and at times prior thereto; in the subassembly area, where damaged sling used to lift/pick-up the UTV and ATV units, exposing employees to struck-by hazards.
Recent events (2)
- — I (O) $7534
- — Z (S) $14063
1910.212 B
- Issued
- Jun 26, 2023
- Abate by
- Jul 7, 2023
- Penalty
- Initial $14,063 · Current $7,534 Reduced
General-duty citation text
29 CFR 1910.212(b): Machines designed for a fixed location were not securely anchored to prevent walking or moving. a) This violation occurred on or about March 16, 2023, and at times prior thereto; in the Assembly area, where the support upright beams for the main overhead crane #TS 2450041-2013 was not securely anchored to prevent moving, exposing employees to the struck-by and crushed-by hazards.
Recent events (2)
- — I (S) $7534
- — Z (S) $14063
1910.303 B02
- Issued
- Jun 26, 2023
- Abate by
- Jul 7, 2023
- Penalty
- Initial $10,046 · Current $7,535 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about March 21, 2023, and at times prior thereto; in the subassembly area: a. Relocatable power tap/power strip was plugged into the extension cord to provide power to the ILiving floor fan, Heat Stream heater, and drill chargers. b. Relocatable power tap/power strip was plugged into the extension cord to provide power to Commercial fan, Pedestal fan and drill chargers. c. Relocatable power tap/power strip was plugged into the extension cord and at the other end of the cord that plugged into another power tap/power strip to provide power to two (2) Pedestal fans and drill chargers.
Recent events (2)
- — I (S) $7534.5
- — Z (S) $10046
1910.305 B01 I
- Issued
- Jun 26, 2023
- Abate by
- Jul 7, 2023
- Penalty
- Initial $10,046 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: a) This violation occurred on or about March 15, 2012 and at times prior thereto; in the assembly area, where opening through which conductor entered electrical panel box was not effectively closed, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $10046
1910.334 A02 II
- Issued
- Jun 26, 2023
- Abate by
- Jul 7, 2023
- Penalty
- Initial $6,026 · Current $0 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) In the subassembly area, electrical extension cord was being used that had damaged insulation.
Recent events (2)
- — I (S) $0
- — Z (S) $6026
1904.32 B06
- Issued
- Jun 26, 2023
- Abate by
- Jul 7, 2023
- Penalty
- Initial $2,009 · Current $1,507 Reduced
General-duty citation text
29 CFR 1904.32(b)(6): The employer did not post the annual summary page no later than February 1 of the year following the year covered by the records and keep the posting in place until April 30. a) The employer did not post the OSHA's Form 300A Annual Summary of Work-Related Injuries and Illnesses of the calendar year 2022 by February 1, 2023 and keep the posting in place until April 30.
Recent events (2)
- — I (O) $1506.75
- — Z (O) $2009
More inspections in this industry (NAICS 336112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346571540.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.