OSHA Inspection: PARKER BUILDERS AND REMODELING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PARKER BUILDERS AND REMODELING, LLC in 4500 STERLING, DOWNERS GROVE, IL 60515 (NAICS 238130). OSHA activity number 346577562.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Parker Builders and Remodeling, LLC — free Get an email when a new federal OSHA severe-injury report for Parker Builders and Remodeling, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4500 STERLING
City
DOWNERS GROVE
State
IL
ZIP
60515
Mailing
17312 S. PARKER ROAD, HOMER GLEN, IL 60491
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 9, 2023
Abate by
Jun 26, 2023
Penalty
Initial $2,009 · Current $1,005 Reduced
29 CFR  1926.100(a):Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.  On or about March 20 2023, employees exposed to overhead hazards were not wearing hard hats, exposing the employees to struck by hazards.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
  • — F (S) $1004.5
  • — C (S) $2009
  • — Z (S) $2009

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 9, 2023
Abate by
Jun 26, 2023
Penalty
Initial $4,688 · Current $2,344 Reduced
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system:  On or about March 20 2023, employees performing residential construction activities were not protected from fall hazards, exposing them to falls of approximately 12.6 feet while performing framing activities.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
  • — F (S) $2344
  • — C (S) $4688
  • — Z (S) $4688

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 9, 2023
Abate by
Jun 26, 2023
Penalty
Initial $4,688 · Current $2,344 Reduced
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  On or about March 20 2023, employees used an extension ladder that did not extend three feet past the point of access, exposing the employee to falls of 11.6 feet.   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
  • — F (S) $2344
  • — C (S) $4688
  • — Z (S) $4688

1926.1053 B16

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 9, 2023
Abate by
Jun 26, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(16):Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired.  On or about March 20 2023, employees used an damaged extension ladder with a missing cleat, exposing the employee to falls of approximately 11.6 feet.   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Parker Builders and Remodeling, LLC's full OSHA safety record →