AGAWAM, MA —
OSHA Inspection: MARUBENI CITIZEN-CINCOM INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MARUBENI CITIZEN-CINCOM INC. in 68 MOYLAN LANE, AGAWAM, MA 01001 (NAICS 333517). OSHA activity number 346580947.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARUBENI CITIZEN-CINCOM INC.
- Site address
- 68 MOYLAN LANE
- City
- AGAWAM
- State
- MA
- ZIP
- 01001
- Mailing
- 68 MOYLAN LANE, AGAWAM, MA 01001
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333517
- Employees
- 61
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C01
- Issued
- May 31, 2023
- Abate by
- May 6, 2024
- Penalty
- Initial $10,046 · Current $5,023 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. 68 Moylan Lane, Agawam MA 01001: On March 17, 2023, and at times prior, the employer had not established an energy control program consisting of written energy control procedures, employee training, and periodic inspections for equipment, such as but not limited to, Milltronics VM-24, to protect employees who performed maintenance and servicing activities. *Abatement Notes: Energy control procedures are required to be documented for all multiple-energy source machines, including but not limited to the Milltronics VM 24. Energy control training is required to be documented and provided for all employees who are, or may be, in an area where energy control procedures may be utilized. A periodic inspection shall include the following elements: - Appointment of an authorized employee to inspect each local procedure for inaccuracies during an actual energy control task - A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use - Certification that the periodic inspections have been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections *Abatement notes are intended only to provide clarity regarding existing requirements under the law or agency policies. Abatement notes do not create (or diminish) legal obligations under the Occupational Safety and Health Act.
Recent events (5)
- — P (S) $5023
- — P (S) $5023
- — P (S) $5023
1910.215 A04
- Issued
- May 31, 2023
- Penalty
- Initial $8,036 · Current $4,018 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): On offhand grinding machines, work rests were not used to support the work. 68 Moylan Lane, Agawam MA 01001: On March 17, 2023, and at times prior, work rests were not provided on the Westward bench grinders.
Recent events (2)
- — I (S) $4018
- — Z (S) $8036
1910.215 B09
- Issued
- May 31, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9):The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch: 68 Moylan Lane, Agawam MA 01001: On March 17, 2023, and at times prior, employees used on the Westward bench grinders that were not equipped with tongue guards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Marubeni Citizen-Cincom INC.
View Marubeni Citizen-Cincom INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333517)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346580947.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.