Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DANIEL ROOFING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DANIEL ROOFING in 2403 BROWN BLVD, ARLINGTON, TX 76006 (NAICS 238160). OSHA activity number 346592454.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Daniel Roofing — free Get an email when a new federal OSHA severe-injury report for Daniel Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
DANIEL ROOFING
Site address
2403 BROWN BLVD
City
ARLINGTON
State
TX
ZIP
76006
Mailing
7509 SAGE HILL COURT, FORT WORTH, TX 76123
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

6 citations on file for this inspection.

1910.132 D01

Serious Gravity 1 1 instance 2 exposed
Issued
May 8, 2023
Abate by
Jun 6, 2023
Penalty
Initial $2,009 · Current $2,009
29 CFR  1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment.   On or about March 17, 2023, where a hazard assessment of the work area would determine the presence of hazards, such as but not limited to overhead electrical powerlines that would necessitate the use of special protective equipment to prevent exposing employees to electric shock and electrocution hazards.  The power lines were energized at approximately 7200 volts.
Recent events (1)
  • — Z (S) $2009

1910.132 D02

Serious Gravity 5 1 instance 2 exposed
Issued
May 8, 2023
Abate by
Jun 6, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed.   On or about March 17, 2023, and at times prior thereto, the employer did not verify a workplace hazard assessment was conducted through a written certification.
Recent events (1)
  • — Z (S) $0

1910.332 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 8, 2023
Abate by
Jun 6, 2023
Penalty
Initial $2,679 · Current $2,679
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  On or about March 17,  20223, and at times prior thereto, employees assigned to power wash apartment complexes near or in the vicinity of energized overhead power lines were not trained in safety-related work practices, exposing the employees to the hazards of electric shock, severe burns and electrocution.
Recent events (1)
  • — Z (S) $2679

1910.333 C03 I A

Serious Gravity 10 1 instance 2 exposed
Issued
May 8, 2023
Abate by
Jun 6, 2023
Penalty
Initial $4,688 · Current $4,688
29 CFR 1910.333(c)(3)(i)(A): When an unqualified person is working in an elevated position near overhead lines, the location shall be such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the following distances:  (1)  For voltages to ground over 50kV - 10 feet (305 cm) plus 4 inches (10 cm) for every 10kV over 50kV.  At the jobsite, employees power washing with an aluminum ladder at a apartment complex made contact with 7,200-volt overhead powerlines. Exposing employees to electric shock, severe burns and electrocution.
Recent events (1)
  • — Z (S) $4688

1910.335 A02 I

Serious Gravity 5 1 instance 2 exposed
Issued
May 8, 2023
Abate by
Jun 6, 2023
Penalty
Initial $2,679 · Current $2,679
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts:  At the jobsite, employees power washing buildings near energized conductors without insulated tools and equipment were exposed to electrical hazards.
Recent events (1)
  • — Z (S) $2679

1910.335 B03

Serious Gravity 5 1 instance 2 exposed
Issued
May 8, 2023
Abate by
Jun 6, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.335(b)(3): Where signs and barricades do not provide sufficient warning and protection from electrical hazards, an attendant was not stationed to warn and protect employees. [55 FR 32016, Aug. 6, 1990]   At the jobsite, employees power washing while standing on a elevated ladder near energized conductors without a trained attendant stationed near where powerlines were located exposed the employee to electrical hazards.
Recent events (1)
  • — Z (S) $0

View Daniel Roofing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346592454.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.