ARLINGTON, TX —
OSHA Inspection: DANIEL ROOFING
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DANIEL ROOFING in 2403 BROWN BLVD, ARLINGTON, TX 76006 (NAICS 238160). OSHA activity number 346592454.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DANIEL ROOFING
- Site address
- 2403 BROWN BLVD
- City
- ARLINGTON
- State
- TX
- ZIP
- 76006
- Mailing
- 7509 SAGE HILL COURT, FORT WORTH, TX 76123
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.132 D01
- Issued
- May 8, 2023
- Abate by
- Jun 6, 2023
- Penalty
- Initial $2,009 · Current $2,009
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment. On or about March 17, 2023, where a hazard assessment of the work area would determine the presence of hazards, such as but not limited to overhead electrical powerlines that would necessitate the use of special protective equipment to prevent exposing employees to electric shock and electrocution hazards. The power lines were energized at approximately 7200 volts.
Recent events (1)
- — Z (S) $2009
1910.132 D02
- Issued
- May 8, 2023
- Abate by
- Jun 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed. On or about March 17, 2023, and at times prior thereto, the employer did not verify a workplace hazard assessment was conducted through a written certification.
Recent events (1)
- — Z (S) $0
1910.332 B01
- Issued
- May 8, 2023
- Abate by
- Jun 6, 2023
- Penalty
- Initial $2,679 · Current $2,679
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: On or about March 17, 20223, and at times prior thereto, employees assigned to power wash apartment complexes near or in the vicinity of energized overhead power lines were not trained in safety-related work practices, exposing the employees to the hazards of electric shock, severe burns and electrocution.
Recent events (1)
- — Z (S) $2679
1910.333 C03 I A
- Issued
- May 8, 2023
- Abate by
- Jun 6, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1910.333(c)(3)(i)(A): When an unqualified person is working in an elevated position near overhead lines, the location shall be such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the following distances: (1) For voltages to ground over 50kV - 10 feet (305 cm) plus 4 inches (10 cm) for every 10kV over 50kV. At the jobsite, employees power washing with an aluminum ladder at a apartment complex made contact with 7,200-volt overhead powerlines. Exposing employees to electric shock, severe burns and electrocution.
Recent events (1)
- — Z (S) $4688
1910.335 A02 I
- Issued
- May 8, 2023
- Abate by
- Jun 6, 2023
- Penalty
- Initial $2,679 · Current $2,679
General-duty citation text
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts: At the jobsite, employees power washing buildings near energized conductors without insulated tools and equipment were exposed to electrical hazards.
Recent events (1)
- — Z (S) $2679
1910.335 B03
- Issued
- May 8, 2023
- Abate by
- Jun 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(b)(3): Where signs and barricades do not provide sufficient warning and protection from electrical hazards, an attendant was not stationed to warn and protect employees. [55 FR 32016, Aug. 6, 1990] At the jobsite, employees power washing while standing on a elevated ladder near energized conductors without a trained attendant stationed near where powerlines were located exposed the employee to electrical hazards.
Recent events (1)
- — Z (S) $0
More inspections at Daniel Roofing
View Daniel Roofing's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346592454.