Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OLYMPIA FOOD INDUSTRIES INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OLYMPIA FOOD INDUSTRIES INC. in 9501 NEVADA AVENUE, FRANKLIN PARK, IL 60131 (NAICS 311412). OSHA activity number 346592884.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Olympia Food Industries INC. — free Get an email when a new federal OSHA severe-injury report for Olympia Food Industries INC. is published. One employer, no account, unsubscribe in one click.
Site address
9501 NEVADA AVENUE
City
FRANKLIN PARK
State
IL
ZIP
60131
Mailing
9501 NEVADA AVENUE, FRANKLIN PARK, IL 60131
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311412
Employees
200
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 16, 2023
Abate by
Sep 12, 2023
Penalty
Initial $10,046 · Current $10,046
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  a) Grinding Room/Gyro Production Room - On or about March 20, 2023, the employer did not ensure that employees who service and disassemble equipment, including the V-Mag Stuffers and vertical bandsaws, understood the purpose and function of the energy control program and were trained in the skills required for the safe application, usage, and removal of the energy isolation and controls.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $10046

1910.147 D

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 16, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) was not done in sequence to achieve energy control by performing the following steps as required by 29 CFR 1910.147(d)(1)-(6):  1. Prepare for shut down by recognizing energy hazards and its controls, 2. Turn off and shut down power to the machinery, 3. Physically locate and operate energy-isolating devices in such a manner as to isolate the machine or equipment from the energy source(s), 4. Affix lockout/tagout devices to each energy isolating device, 5. Render safe all potentially hazardous stored or residual energy, and 6. Verify isolation and de-energization of machinery have been accomplished prior to starting the maintenance and/or servicing work:  a) Grinding Room/Gyro Production Room - On or about March 20, 2023, employees were exposed to machine hazards associated with pinch points and moving parts while disassembling equipment, including the V-Mag Stuffers. The employer did not implement energy control application steps as the machine was not shut down or turned off to perform servicing tasks [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from moving equipment and pinch points.  No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $0

View Olympia Food Industries INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346592884.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.