Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SEGOVIA GENERAL CONSTRUCTION LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of SEGOVIA GENERAL CONSTRUCTION LLC in 14-01 RIVER RD, FAIR LAWN, NJ 07410 (NAICS 238140). OSHA activity number 346595226.

Watch Segovia General Construction LLC — free Get an email when a new federal OSHA severe-injury report for Segovia General Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
14-01 RIVER RD
City
FAIR LAWN
State
NJ
ZIP
07410
Mailing
323 NORTH 5 STREET, NEWARK, NJ 07101
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $4018.00 · Current $2411.00 Reduced
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  a) Building Exterior:  Employees were exposed to eye/face injuries while applying stucco. Employee was not protected with any type of eye/face protection, on or about 3/28/23
Recent events (2)
  • — I (S) $2410.8
  • — Z (S) $4018

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4688.00 · Current $2813.00 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)   a) Building Exterior:  Employees were exposed to an 18 foot fall hazard while doing demo from a tubular welded frame scaffold with missing planks. Scaffold was not fully decked or planked between front and uprights, on or about 3/28/23
Recent events (2)
  • — I (S) $2812.8
  • — Z (S) $4688

1926.451 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4688.00 · Current $2813.00 Reduced
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph.  a) Building Exterior: Employees were engaged in demolition activities from a pipe scaffold that was not restrained from tipping by guying ,tying, bracing or equivalent means, on or about 3/28/23.
Recent events (2)
  • — I (S) $2812.8
  • — Z (S) $4688

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4688.00 · Current $2813.00 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.   a) Building Exterior: A proper means of access was not provided for the scaffold system. Thereby exposing employees to a fall hazard of approximately 18 feet, on or about 3/28/23.
Recent events (2)
  • — I (S) $2812.8
  • — Z (S) $4688

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4688.00 · Current $2813.00 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  a) Building Exterior: Employees were exposed to a 18 foot fall hazard while doing demo from a pipe scaffold that was not provided with a guardrail system or other means of fall protection, on or about 3/28/23
Recent events (2)
  • — I (S) $2812.8
  • — Z (S) $4688

1926.1153 C02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $4018.00 · Current $2411.00 Reduced
29 CFR 1926.1153(c)(2)(ii): Water was not applied at flow rates sufficient to minimize release of visible dust for tasks performed using wet methods:  a) Building Exterior: Employees did not apply water to minimize the release of visible dust while dry cutting a concrete and jackhammering the fa�ade of a commercial building, on or about 3/28/23
Recent events (2)
  • — I (S) $2410.8
  • — Z (S) $4018

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346595226.