FAIR LAWN, NJ ·
OSHA Inspection: SEGOVIA GENERAL CONSTRUCTION LLC
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of SEGOVIA GENERAL CONSTRUCTION LLC in 14-01 RIVER RD, FAIR LAWN, NJ 07410 (NAICS 238140). OSHA activity number 346595226.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEGOVIA GENERAL CONSTRUCTION LLC
- Site address
- 14-01 RIVER RD
- City
- FAIR LAWN
- State
- NJ
- ZIP
- 07410
- Mailing
- 323 NORTH 5 STREET, NEWARK, NJ 07101
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1926.102 A01
- Issued
- Mar 30, 2023
- Penalty
- Initial $4,018 · Current $2,411 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) Building Exterior: Employees were exposed to eye/face injuries while applying stucco. Employee was not protected with any type of eye/face protection, on or about 3/28/23
Recent events (2)
- · I (S) $2410.8
- · Z (S) $4018
1926.451 B01
- Issued
- Mar 30, 2023
- Penalty
- Initial $4,688 · Current $2,813 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Building Exterior: Employees were exposed to an 18 foot fall hazard while doing demo from a tubular welded frame scaffold with missing planks. Scaffold was not fully decked or planked between front and uprights, on or about 3/28/23
Recent events (2)
- · I (S) $2812.8
- · Z (S) $4688
1926.451 C01
- Issued
- Mar 30, 2023
- Penalty
- Initial $4,688 · Current $2,813 Reduced
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. a) Building Exterior: Employees were engaged in demolition activities from a pipe scaffold that was not restrained from tipping by guying ,tying, bracing or equivalent means, on or about 3/28/23.
Recent events (2)
- · I (S) $2812.8
- · Z (S) $4688
1926.451 E01
- Issued
- Mar 30, 2023
- Penalty
- Initial $4,688 · Current $2,813 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) Building Exterior: A proper means of access was not provided for the scaffold system. Thereby exposing employees to a fall hazard of approximately 18 feet, on or about 3/28/23.
Recent events (2)
- · I (S) $2812.8
- · Z (S) $4688
1926.451 G01
- Issued
- Mar 30, 2023
- Penalty
- Initial $4,688 · Current $2,813 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) Building Exterior: Employees were exposed to a 18 foot fall hazard while doing demo from a pipe scaffold that was not provided with a guardrail system or other means of fall protection, on or about 3/28/23
Recent events (2)
- · I (S) $2812.8
- · Z (S) $4688
1926.1153 C02 II
- Issued
- Mar 30, 2023
- Penalty
- Initial $4,018 · Current $2,411 Reduced
General-duty citation text
29 CFR 1926.1153(c)(2)(ii): Water was not applied at flow rates sufficient to minimize release of visible dust for tasks performed using wet methods: a) Building Exterior: Employees did not apply water to minimize the release of visible dust while dry cutting a concrete and jackhammering the fa�ade of a commercial building, on or about 3/28/23
Recent events (2)
- · I (S) $2410.8
- · Z (S) $4018
More inspections in this industry (NAICS 238140)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 346595226.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.