Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TIMKEN DRIVES LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TIMKEN DRIVES LLC in 901 19TH AVE, FULTON, IL 61252 (NAICS 333613). OSHA activity number 346604747.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Timken Drives LLC — free Get an email when a new federal OSHA severe-injury report for Timken Drives LLC is published. One employer, no account, unsubscribe in one click.
Establishment
TIMKEN DRIVES LLC
Site address
901 19TH AVE
City
FULTON
State
IL
ZIP
61252
Mailing
901 19TH AVE, FULTON, IL 61252
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333613
Employees
529
Ownership type
A

1 citation on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 28, 2023
Abate by
Aug 14, 2023
Penalty
Initial $15,625 · Current $11,000 Reduced
29 CFR  1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  a) On or about March 17, 2023, the employer did not ensure that employees implemented energy control application steps prior to troubleshooting the Heavy C Blockbuilder, Minster 90-60, (SN 90-60-5205).  Hazardous energy was not isolated prior to employees engaging in servicing and maintenance activities, exposing employees to laceration and amputation hazards from unexpected movement of the machine.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.   Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $11000
  • — Z (S) $15625

View Timken Drives LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346604747.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.