Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WELLMADE INDUSTRIES MFR. N.A LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WELLMADE INDUSTRIES MFR. N.A LLC in 1 WELLMADE DRIVE, CARTERSVILLE, GA 30121 (NAICS 321918). OSHA activity number 346606411.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wellmade Industries MFR. N.A LLC — free Get an email when a new federal OSHA severe-injury report for Wellmade Industries MFR. N.A LLC is published. One employer, no account, unsubscribe in one click.
Site address
1 WELLMADE DRIVE
City
CARTERSVILLE
State
GA
ZIP
30121
Mailing
P.O. BOX 52897, ATLANTA, GA 30355
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
160
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 22, 2023
Abate by
Oct 23, 2023
Penalty
Initial $11,050 · Current $11,050
29 CFR  1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation   a) Grinding Department: On or about April 03, 2023, and at times prior, the employer exposed an employee to electrical shock hazards, in that the authorized employee working on 480 Volts electrical panels did not receive training  in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.
Recent events (1)
  • — Z (S) $11050

1910.147 C07 I C

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 22, 2023
Abate by
Oct 23, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(C): Employees whose work operations were in an area where energy control procedures were utilized were not instructed about the prohibition relating to attempts to restart or reenergize machines or equipment which are locked or tagged out.   a) Grinding Department: On or about April 03, 2023, and at times prior, the employer exposed employees to electrical, struck-by and caught-in hazards, in that affected employees were not instructed on lock-out/tag-out procedures and the prohibition to restarting or re-energize equipment, such as but not limited to the Grinder, that have been locked out or tagged out.
Recent events (1)
  • — Z (S) $0

1904.32 B06

Other-than-serious 1 instance 65 exposed
Issued
Sep 22, 2023
Penalty
Initial $2,210 · Current $2,210
29 CFR 1904.32(b)(6): The OSHA 300-A Summary was not posted by February 1 of the year following the year covered by the records and/or kept in place until April 30.   a) Worksite: The employer did not ensure the OSHA 300-A Summary for calendar year 2022 was posted by February 1, 2023.
Recent events (1)
  • — Z (O) $2210

View Wellmade Industries MFR. N.A LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346606411.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.