MARYSVILLE, OH —
OSHA Inspection: UNIVENTURE INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of UNIVENTURE INC in 16710 SQUARE DRIVE, MARYSVILLE, OH 43040 (NAICS 322230). OSHA activity number 346607971.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIVENTURE INC
- Site address
- 16710 SQUARE DRIVE
- City
- MARYSVILLE
- State
- OH
- ZIP
- 43040
- Mailing
- 4266 TULLER RD, DUBLIN, OH 43017
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322230
- Employees
- 27
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 19, 2023
- Abate by
- Aug 8, 2023
- Penalty
- Initial $10,938 · Current $10,938
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance. a. On or about April 3, 2023, the employer did not ensure that specific procedures were developed for the control of potentially hazardous energy when an employee was engaged in maintenance and servicing for the Nilpeter printing machine, thereby exposing the employee to being caught-in/between rollers and ingoing nip points due to two energy sources present, electrical and pneumatic. b. On or about April 3, 2023, the employer did not ensure that specific procedures were developed for the control of potentially hazardous energy when an employee was engaged in maintenance and serving for the Aquaflex printing machine, thereby exposing the employee to being caught-in/between rollers and ingoing nip points due to two energy sources present, electrical and pneumatic.
Recent events (2)
- — I (S) $10938
- — Z (S) $10938
1910.147 C07 I A
- Issued
- Jul 19, 2023
- Abate by
- Aug 8, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a. On or about April 3, 2023, the employer did not ensure that the employee performing servicing and maintenance on the Nilpeter and Aquaflex printing machines, such as replacing bolts and parts inside the machine, received training in the recognition of hazardous energy sources, the type and magnitude of the energy in the workplace, and the methods and means necessary for energy isolation and control.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D
- Issued
- Jul 19, 2023
- Abate by
- Aug 8, 2023
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence as outlined in paragraphs (d)(1)-(d)(6) of this standard: a. On or about April 1, 2023, and at times prior, the employer failed to apply energy control procedures for covered activated performed on the Nilpeter printing press. The employer did not ensure that actions were taken in the required sequence to dissipate residual energy from the pneumatic system and verify isolation of the energy. Maintenance personnel perform covered activities, including, repair and troubleshooting maintenance, without performance of the actions required by 29 CFR 1910.147(d)(1)-(d)(6). During covered activities maintenance employees have exposure to potential caught-in and struck by hazards associated with the rollers and press tools. b. On or about April 1, 2023, and at times prior, the employer failed to apply energy control procedures for covered activities performed on the Aquaflex printing press. The employer did not ensure that actions were taken in the required sequence to dissipate residual energy from the pneumatic system and verify isolation of the energy. Maintenance personnel perform covered activities, including, repair and troubleshooting maintenance, without performance of the actions required by 29 CFR 1910.147(d)(1)-(d)(6). During covered activities maintenance employees have exposure to potential caught-in and struck by hazards associated with the rollers and press tools.
Recent events (2)
- — I (S) $0
- — Z (S) $10938
1910.212 A01
- Issued
- Jul 19, 2023
- Abate by
- Aug 8, 2023
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. a. On or about April 3, 2023, Univenture INC did not provide one or more methods of machine guarding to protect the operator and other employees in the Aquaflex machine area from hazards such as those created by point of operation and ingoing nip points, for the powered printing application roller at the operator station. b. On or about April 3, 2023, Univenture INC did not provide one or more methods of machine guarding to protect the operator and other employees in the Nilpeter machine area from hazards such as those created by point of operation and ingoing nip points, for the powered printing application roller at the operator station. c. On or about April 3, 2023, Univenture INC did not provide one or more methods of machine guarding to protect the operator and other employees for the Gannicott Limited Independent Drive Batch Stacker model 10333, due to the stacker belts being exposed and accessible to employees during normal operation, exposing employees to hazards such as those created by point of operation and ingoing nip points. d. On or about April 3, 2023, Univenture INC did not provide one or more methods of machine guarding to protect the operator and other employees for the Gannitcott Limited Independent Drive Batch Stacker model 9575, due to the stacker belts being exposed and accessible to employees during normal operation, exposing employees to hazards such as those created by points of operation and ingoing nip points.
Recent events (2)
- — I (S) $0
- — Z (S) $10938
More inspections at Univenture INC
View Univenture INC's full OSHA safety record →
More inspections in this industry (NAICS 322230)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346607971.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.