OSHA Inspection: COMPLETE PIPE SERVICES, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COMPLETE PIPE SERVICES, LLC. in WOLFBONE REV GF STATE T7-50-38 C, PECOS, TX 79772 (NAICS 213112). OSHA activity number 346609878.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Complete Pipe Services, LLC. — free Get an email when a new federal OSHA severe-injury report for Complete Pipe Services, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
WOLFBONE REV GF STATE T7-50-38 C
City
PECOS
State
TX
ZIP
79772
Mailing
PO BOX 1753, KILGORE, TX 75662
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
31
Ownership type
A

3 citations on file for this inspection.

1910.243 C03

Serious Gravity 5 1 instance 1 exposed
Issued
May 4, 2023
Abate by
May 23, 2023
Penalty
Initial $6,250 · Current $5,200 Reduced
29 CFR  1910.243(c)(3):Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel:  Rig Site: On or about April 04, 2023, an employee of a third-party was observed using a DEWALT angle grinder (Model # D28110 Serial # 158692) without the guard. The employee was exposed to struck-by hazards.
Recent events (2)
  • — I (S) $5200
  • — Z (S) $6250

1910.334 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 4, 2023
Penalty
Initial $9,376 · Current $0 Reduced
29 CFR  1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  Rig Site: On or about April 4, 2023, a damaged extension cord was being utilized that was being powered by 7500-Watt Champion Generator to an angled grinder. This condition exposed employees to electrical hazards such as shock and/or burns.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9376

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
May 4, 2023
Penalty
Initial $877 · Current $800 Reduced
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Rig Site: On or about April 04, 2023, two extension cords were daisy chained to one another. Employees were exposed to electrical shock hazards.