OSHA Inspection: GOODWILL TITUSVILLE PA

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GOODWILL TITUSVILLE PA in 115 DIAMOND STREET, TITUSVILLE, PA 16354 (NAICS 453310). OSHA activity number 346613771.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Goodwill Titusville PA — free Get an email when a new federal OSHA severe-injury report for Goodwill Titusville PA is published. One employer, no account, unsubscribe in one click.
Site address
115 DIAMOND STREET
City
TITUSVILLE
State
PA
ZIP
16354
Mailing
115 DIAMOND STREET, TITUSVILLE, PA 16354
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453310
Employees
134
Ownership type
A

4 citations on file for this inspection.

1910.22 A02

Deleted Serious Gravity 1 1 instance 6 exposed
Issued
May 31, 2023
Abate by
Jun 27, 2023
Penalty
Initial $5,122 · Current $0 Reduced
29 CFR  1910.22(a)(2): The employer did not ensure that the  floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided.  a.)  Goodwill Titusville PA ; back storeroom - On or about 4/5/23, and at times prior thereto, during and after periods of rain, water leaks from the ceiling and from the exterior sidewalk under the Donation Door into the work areas where employees are located.  A floor drain, or similar, is not available in the area.    ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5122

1910.305 G01 IV A

Serious Gravity 5 1 instance 6 exposed
Issued
May 31, 2023
Abate by
Jul 27, 2023
Penalty
Initial $6,831 · Current $4,000 Reduced
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a.)  Goodwill Titusville PA ; back store room - On or about 4/5/23, and at times prior thereto,  the microwave, refrigerator and time clock were attached  to a surge protector.  The surge protector was connected to a flexible extension cord. The extension cord was run to the other side of the room and plugged in.    ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $6831

1910.303 G02 II

Serious Gravity 5 1 instance 6 exposed
Issued
May 31, 2023
Abate by
Jul 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:   a.)  Goodwill Titusville PA ; back store room - On or about 4/5/23, and at times prior thereto, the cable assembly that powered the outside sign and lighting  was run through the wall.  The cable assembly was not protected  by devices such as rubber sleeves, grommets, and/or conduit to prevent physical damage such as rubbing and chafing.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 1 1 instance 6 exposed
Issued
May 31, 2023
Abate by
Jul 27, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.   a.)  Goodwill Titusville PA ; back store room - On or about 4/5/23, and at times prior thereto,  an electrical box on the wall had a missing  knockout.  The box and cord  powered the light outside the donation door.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346613771.