Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A-1 GUAMAN HOME IMPROVEMENT INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of A-1 GUAMAN HOME IMPROVEMENT INC. in 143 ENDICOTT ST., LACONIA, NH 03246 (NAICS 238160). OSHA activity number 346624174.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A-1 Guaman Home Improvement INC. — free Get an email when a new federal OSHA severe-injury report for A-1 Guaman Home Improvement INC. is published. One employer, no account, unsubscribe in one click.
Site address
143 ENDICOTT ST.
City
LACONIA
State
NH
ZIP
03246
Mailing
32 HUNTINGTON ST., BROCKTON, MA 02301
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
May 10, 2023
Abate by
May 30, 2023
Penalty
Initial $4,688 · Current $4,000 Reduced
29 CFR  1926.501(b)(10):Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:  a. Site - Employees installing rubber membrane roofing were not protected from falls of between 9 and 18 feet when fall protection was not being used or installed.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4688

1926.1052 C01 I

Serious Gravity 1 1 instance 2 exposed
Issued
May 10, 2023
Abate by
May 30, 2023
Penalty
Initial $2,009 · Current $0 Reduced
29 CFR  1926.1052(c)(1)(i):Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  Site- Employees using an interior stairway to gain access to and from upper stories of the building were exposed to fall hazards when the stairway was not equipped with a handrail.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2009

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 10, 2023
Abate by
May 30, 2023
Penalty
Initial $3,349 · Current $0 Reduced
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a. Site- Employees performing roofing work were exposed to fall hazards when the side rails of an aluminum ladder used to gain access to and from the upper roof level were not extended at least 3 feet above the upper roofs eave.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3349

View A-1 Guaman Home Improvement INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346624174.