Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HECTOR ESCOBAR DBA ESCOBAR REMODELING AND SERVICES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HECTOR ESCOBAR DBA ESCOBAR REMODELING AND SERVICES INC. in 4610 BRIGANTINE DR., HOFFMAN ESTATES, IL 60192 (NAICS 238170). OSHA activity number 346627193.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hector Escobar DBA Escobar Remodeling and Services INC. — free Get an email when a new federal OSHA severe-injury report for Hector Escobar DBA Escobar Remodeling and Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
4610 BRIGANTINE DR.
City
HOFFMAN ESTATES
State
IL
ZIP
60192
Mailing
188 GLADSTONE DR. APT 201, GLENDALE HEIGHTS, IL 60139
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

3 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 3 exposed
Issued
Oct 2, 2023
Abate by
Oct 20, 2023
Penalty
Initial $376 · Current $376
29 CFR  1903.19(c)(1):  The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   Hector Escobar dba Escobar Remodeling and Services Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation 1, Item 1a, 1926.451(g)(1) Citation 1, Item 1b, 1926.501(b)(13)  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (1)
  • — Z (O) $376

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 13, 2023
Abate by
Jun 20, 2023
Penalty
Initial $4,688 · Current $4,688
29 CFR  1926.451(g)(1):  Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.   a) On April 12, 2023, employees were exposed to the hazard of falling while performing siding work from a pump-jack scaffold platform elevated approximately 12.4 feet above the ground.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4688

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 13, 2023
Abate by
Jun 20, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   a) On April 12, 2023, employees were exposed to fall hazards of approximately 10 feet while performing siding work from the roof of a residential structure.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346627193.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.