Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUNPOWER CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUNPOWER CORPORATION in 17339 ORIOLE AVE., TINLEY PARK, IL 60477 (NAICS 221114). OSHA activity number 346627748.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunpower Corporation — free Get an email when a new federal OSHA severe-injury report for Sunpower Corporation is published. One employer, no account, unsubscribe in one click.
Site address
17339 ORIOLE AVE.
City
TINLEY PARK
State
IL
ZIP
60477
Mailing
2380 VANTAGE DRIVE,, ELGIN, IL 60124
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
3
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 5 2 instances 2 exposed
Issued
May 18, 2023
Penalty
Initial $9,376 · Current $6,563 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b)  a. On or about April 10, 2023, at the above addressed jobsite, employees performing residential solar panel installation, eight (8) feet four (4) inches above ground, were not protected from falls, thereby exposing the employees to fall hazards.   b. On or about April 10, 2023, at the above addressed jobsite, an employee performing residential solar panel installation, twelve (12) feet five (5) inches above ground, was not protected from falls, thereby exposing the employee to fall hazards.
Recent events (2)
  • — I (S) $6563.2
  • — Z (S) $9376

View Sunpower Corporation's full OSHA safety record →