OSHA Inspection: ROOF PROS STORM DIVISION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROOF PROS STORM DIVISION, INC. in 6045 A1A SOUTH, SAINT AUGUSTINE, FL 32080 (NAICS 238160). OSHA activity number 346640568.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roof Pros Storm Division, INC. — free Get an email when a new federal OSHA severe-injury report for Roof Pros Storm Division, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6045 A1A SOUTH
City
SAINT AUGUSTINE
State
FL
ZIP
32080
Mailing
3501-B NORTH PONCE DE LEON BLVD #357, SAINT AUGUSTINE, FL 32084
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 10, 2023
Penalty
Initial $10,313 · Current $7,219 Reduced
29 CFR 1926.501(b)(11):   Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:   a. On a second story 6:12 pitched roof, at a temporary worksite located at 6045 A1A South in Saint Augustine, Florida: On or about April 18, 2023, the employer exposed subcontracted employees to fall hazards ranging from 18 to 28 foot, in that in that fall protection, was not utilized, while performing roofing work.  Roof Pros Storm Division, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1534908, citation number 1, item number 1, and was affirmed as a final order on 10/20/2021, with respect to a workplace located at 979 Garrison Drive, Saint Augustine, FL 32080.
Recent events (2)
  • — I (S) $7219.1
  • — Z (R) $10313

1926.1053 B01

Other-than-serious 1 instance 4 exposed
Issued
Jul 10, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(1):  Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a.   While accessing a second story 6:12 pitched roof, at a temporary worksite located at 6045 A1A South in Saint Augustine, Florida:  On or about April 18, 2023, the employer exposed subcontracted employees to fall hazards ranging from 6 to 18 foot, in that the side rails of a potable ladder were not extended at least 3 feet above the upper landing surface the roof, when employees climbed or descended the ladder.