Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EUROCARS COLLISION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of EUROCARS COLLISION in 721 YUMA STREET, COLORADO SPRINGS, CO 80909 (NAICS 811198). OSHA activity number 346645500.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eurocars Collision — free Get an email when a new federal OSHA severe-injury report for Eurocars Collision is published. One employer, no account, unsubscribe in one click.
Establishment
EUROCARS COLLISION
Site address
721 YUMA STREET
City
COLORADO SPRINGS
State
CO
ZIP
80909
Mailing
721 YUMA STREET, COLORADO SPRINGS, CO 80909
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811198
Employees
35
Ownership type
A

4 citations on file for this inspection.

1910.134 G01 I A

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 21, 2023
Abate by
Jul 18, 2023
Penalty
Initial $4,687 · Current $2,812 Reduced
29 CFR  1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  (a) 721 North Yuma Street, Colorado Springs, CO: On or about April 18th, 2023, and at times prior, the employer, Eurocars Collision, did not ensure its detailing employees kept their faces clean-shaven from facial hair while using a half-face electrometric respirator.
Recent events (2)
  • — I (S) $2812.2
  • — Z (S) $4687

1910.134 H02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 21, 2023
Abate by
Jul 18, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.134(h)(2)(i):Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:  (a) 721 North Yuma Street, Colorado Springs, CO: On or about April 18, 2023, and at times prior, the employer, Eurocars Collision, did not ensure half-face respirators used by the detailing staff were stored properly to prevent contamination and damage. This exposed employees to illness while using the half-face respirators.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 A01

Other-than-serious 1 instance 10 exposed
Issued
Jun 21, 2023
Abate by
Jul 18, 2023
Penalty
Initial $877 · Current $526 Reduced
29 CFR  1910.22(a): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces were kept in a clean, orderly, and sanitary condition.  a) 721 North Yuma Street, Colorado Springs , CO: On or about April 18, 2023, and at times prior, the employer, Eurocars Collision, exposed its employees to slip, trip, and fall hazards within the main service shop in that, cords were run across floors and multiple tools, carts, bottles and vehicle parts were located throughout the shop area not allowing for clear passage and walking through the shop and bays.
Recent events (2)
  • — I (O) $526.2
  • — Z (O) $877

1910.303 G01

Other-than-serious 1 instance 10 exposed
Issued
Jun 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) 721 North Yuma Street, Colorado Springs, CO: The employer, Eurocars Collision, exposed employees to electrical and fire hazards in that no space was maintained to access the electrical panels in order to conduct maintenance or safe operations within the panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346645500.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.