Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VORTEQ COIL FINISHERS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of VORTEQ COIL FINISHERS, LLC in 15920 NELSON ROAD, WOODSTOCK, IL 60098 (NAICS 332812). OSHA activity number 346645526.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vorteq Coil Finishers, LLC — free Get an email when a new federal OSHA severe-injury report for Vorteq Coil Finishers, LLC is published. One employer, no account, unsubscribe in one click.
Site address
15920 NELSON ROAD
City
WOODSTOCK
State
IL
ZIP
60098
Mailing
15920 NELSON ROAD, WOODSTOCK, IL 60098
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
28
Ownership type
A

5 citations on file for this inspection.

1910.133 A01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 15, 2023
Abate by
Oct 23, 2023
Penalty
Initial $6,875 · Current $0 Reduced
29 CFR  1910.133(a)(1): Eye and face protection. General requirements.  The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  On or about April 18, 2023, the employer did not ensure that employees wore chemical splash goggles while working with Bulk-Bond NP-250 (corrosive), Bulk Kleen 841 NA (corrosive), and E-CLPS 2950 SI (corrosive).  Certification of abatement is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (3)
  • — F (S) $0
  • — C (S) $6875
  • — Z (S) $6875

1910.151 C

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 15, 2023
Abate by
Oct 23, 2023
Penalty
Initial $8,595 · Current $0 Reduced
29 CFR  1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use.  On or about April 18, 2023, an eyewash station was not provided where employees use products including, but not limited to, Bulk-Bond NP-250 (corrosive), Bulk Kleen 841 NA (corrosive), and E-CLPS 2950 SI (corrosive).  Documentation of abatement is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
  • — F (S) $0
  • — C (S) $8595
  • — Z (S) $8595

1910.303 G01 I A

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 15, 2023
Abate by
Apr 15, 2024
Penalty
Initial $5,156 · Current $4,125 Reduced
29 CFR  1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:   On or about April 18, 2023, an electrical panel (110 volt) located on the shop floor was obstructed by a dust collector exposing employees to electrical shock and electrical fires.  Certification of abatement is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (3)
  • — F (S) $4125
  • — C (S) $5156
  • — Z (S) $5156

1910.1200 F06 I

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Sep 15, 2023
Abate by
Apr 15, 2024
Penalty
Initial $5,156 · Current $4,125 Reduced
29 CFR  1910.1200(f)(6)(i):The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v).  On or about April 18, 2023, employees were exposed to chemical hazards from unlabeled containers of oil and methyl ethyl ketone that were not appropriately labeled to inform employees of the contents.     Certification of abatement is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (3)
  • — F (O) $4125
  • — C (S) $5156
  • — Z (S) $5156

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Sep 15, 2023
Abate by
Apr 15, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:   On or about April 18, 2023, employees permitted to voluntarily use N-95 filtering facepiece respirators were not provided Appendix D of the standard.  Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Vorteq Coil Finishers, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346645526.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.