Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G.D. ROOFING AND SIDING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of G.D. ROOFING AND SIDING LLC in 1178 FOREST RISE DRIVE, WESTERVILLE, OH 43081 (NAICS 238160). OSHA activity number 346646284.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G.D. Roofing and Siding LLC — free Get an email when a new federal OSHA severe-injury report for G.D. Roofing and Siding LLC is published. One employer, no account, unsubscribe in one click.
Site address
1178 FOREST RISE DRIVE
City
WESTERVILLE
State
OH
ZIP
43081
Mailing
1684 MARSHDALE AVE, COLUMBUS, OH 43223
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 31, 2023
Abate by
Aug 18, 2023
Penalty
Initial $3,349 · Current $2,512 Reduced
29 CFR  1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.  a) G.D. Roofing and Siding LLC, at a jobsite located at 1178 Forest Rise Dr, Westerville, OH 43081: On or about April 20, 2023, the employer failed to initiate and maintain safety/health programs such as but not limited to personal protective equipment program, electrical safety program and a fall protection program for employees conducting roofing work.
Recent events (2)
  • — I (S) $2511.75
  • — Z (S) $3349

1926.21 B02

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 31, 2023
Abate by
Aug 18, 2023
Penalty
Initial $3,349 · Current $0 Reduced
29 CFR  1926.21(b)(2):The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.  a) G.D. Roofing and Siding LLC, at a jobsite located at 1178 Forest Rise Dr, Westerville, OH 43081: On or about April 20, 2023: the employer failed to train employees on the hazards found on the worksite and/or procedures to control/eliminate the hazards for employees conducting residential roofing work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3349

1926.102 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Jul 31, 2023
Abate by
Aug 10, 2023
Penalty
Initial $4,688 · Current $0 Reduced
29 CFR  1926.102(a)(1):The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  a) G.D. Roofing and Siding LLC, at a jobsite located at 1178 Forest Rise Dr, Westerville, OH 43081: On or about April 20, 2023, the employer did not ensure employees wore safety glasses while utilizing portable power tools and pneumatic nailers that presented struck-by hazards to the eyes and face. Employees did not utilize eye protection. The following condition exposed employees to struck-by hazards to the eyes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4688

1926.404 B01 III C

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 31, 2023
Abate by
Aug 14, 2023
Penalty
Initial $3,349 · Current $2,512 Reduced
29 CFR  1926.404(b)(1)(iii)(C):Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired.  a) G.D. Roofing and Siding LLC, at a jobsite located at 1178 Forest Rise Dr, Westerville, OH 43081: On or about April 20, 2023, the employer did not ensure a portable power cord used to power a circular saw was visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage and for indications of possible internal damage. Roofers used the portable power cord with missing insulation along its length and a missing ground prong, which exposed the employees to electrical contact hazards.
Recent events (2)
  • — I (S) $2511.75
  • — Z (S) $3349

1926.404 F06

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 31, 2023
Abate by
Aug 10, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.404(f)(6):Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.  a) G.D. Roofing and Siding LLC, at a jobsite located at 1178 Forest Rise Dr, Westerville, OH 43081: On or about April 20, 2023, the employer did not ensure employees using portable power cords to provide power to a circular saw were protected from electrical contact hazards. Roofers used a portable cord without a ground prong, which exposed the employees electrical contact hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Jul 31, 2023
Abate by
Aug 10, 2023
Penalty
Initial $4,688 · Current $3,517 Reduced
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a) G.D. Roofing and Siding LLC, at a jobsite located at 1178 Forest Rise Dr, Westerville, OH 43081: On or about April 20, 2023, the employer did not ensure employees were protected from falls while engaged in residential construction activities. Employees were performing re-roofing activities without being connected to a fall protection system. The following condition exposed employees to falls of between seven and 19 feet.
Recent events (2)
  • — I (S) $3516.5
  • — Z (S) $4688

View G.D. Roofing and Siding LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346646284.