Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BUTLER WIRE & METAL PRODUCTS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BUTLER WIRE & METAL PRODUCTS INC. in N60 W15288 BOBOLINK AVENUE, MENOMONEE FALLS, WI 53051 (NAICS 332618). OSHA activity number 346647985.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Butler Wire & Metal Products INC. — free Get an email when a new federal OSHA severe-injury report for Butler Wire & Metal Products INC. is published. One employer, no account, unsubscribe in one click.
Site address
N60 W15288 BOBOLINK AVENUE
City
MENOMONEE FALLS
State
WI
ZIP
53051
Mailing
N60 W15288 BOBOLINK AVENUE, MENOMONEE FALLS, WI 53051
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
12
Ownership type
A

5 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 9, 2023
Abate by
Jul 7, 2023
Penalty
Initial $4,465 · Current $2,700 Reduced
29 CFR  1910.147(c)(7)(i) (A):Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  a) On or about April 20, 2023, at the workplace located at N60 W15288 Bobolink Avenue Menomonee Falls, WI 53051, the employer did not ensure employees received training as authorized employees before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury. The machine or equipment shall be isolated from the energy source and rendered inoperative for employees that were engaged in service and maintenance activities on equipment, such as, but not limited to resistance welding machines, press brakes and where the unexpected energizing, start up or release of stored energy could occur and cause injury.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4465

1910.147 C07 I B

Serious Gravity 5 6 instances 7 exposed
Issued
Jun 9, 2023
Abate by
Jul 7, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:   a) On or about April 20, 2023, at the workplace located at  N60 W15288 Bobolink Avenue Menomonee Falls, WI 53051, the employer did not conduct employee training to ensure that each affected employee was instructed in the purpose and use of the energy control procedure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.255 B04

Serious Gravity 10 6 instances 11 exposed
Issued
Jun 9, 2023
Abate by
Jul 28, 2023
Penalty
Initial $6,250 · Current $3,700 Reduced
29 CFR  1910.255(b)(4):Guarding. All press welding machine operations, where there was a possibility of the operator's fingers being under the point of operation, shall be effectively guarded by the use of a device such as an electronic eye safety circuit, two hand controls or protection similar to that prescribed for punch press operation, 1910.217. All chains, gears, operating bus linkage, and belts shall be protected by adequate guards, in accordance with 1910.219 of this part.  a.  At the workplace, in the processing area, W4/Cage welder resistance welding machine did not have the point of operation guarded, thereby exposing employees to an amputation hazard.   b.   At the workplace, in the processing area, W10 resistance welding machine did not have the point of operation guarded, thereby exposing employees to an amputation hazard.   c.   At the workplace, in the processing area, W11 resistance welding machine did not have the point of operation guarded, thereby exposing employees to an amputation hazard.   d.   At the workplace, in the processing area, W12 resistance welding machine did not have the point of operation guarded, thereby exposing employees to an amputation hazard.   e.  At the workplace, in the processing area, W15 resistance welding machine did not have the point of operation guarded, thereby exposing employees to an amputation hazard.   f.   At the workplace, in the processing area, W16 resistance welding machine did not have the point of operation guarded, thereby exposing employees to an amputation hazard.
Recent events (2)
  • — I (S) $3700
  • — Z (S) $6250

1910.255 E

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 9, 2023
Abate by
Jul 28, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.255(e):Maintenance. Periodic inspection shall be made by qualified maintenance personnel, and a certification record maintained. The certification record shall include the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, for the equipment inspected. The operator shall be instructed to report any equipment defects to his supervisor and the use of the equipment shall be discontinued until safety repairs have been completed. [39 FR 23502, June 27, 1974, as amended at 40 FR 18426, Apr. 28, 1975; 55 FR 13710, Apr. 11, 1990]  a.  At the workplace, periodic inspections were not performed or documented for the resistance welding equipment to identify equipment defects and hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Other-than-serious 1 instance 3 exposed
Issued
Jun 9, 2023
Abate by
Jul 28, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.   a.  At the workplace located at N60 W15288 Bobolink Avenue Menomonee Falls, WI 53051, the employer did not conduct periodic inspections of energy control procedures annually to ensure that the requirements of this standard are being followed for employees that were engaged in activities on equipment, such as, but not limited to, automatic resistance welding machines, where the unexpected energizing, start up or release of stored energy could occur and cause injury.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Butler Wire & Metal Products INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346647985.