OSHA Inspection: UNITED STEEL & FASTENERS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of UNITED STEEL & FASTENERS, INC. in 1500 INDUSTRIAL DR, ITASCA, IL 60143 (NAICS 332510). OSHA activity number 346655483.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Steel & Fasteners, INC. — free Get an email when a new federal OSHA severe-injury report for United Steel & Fasteners, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1500 INDUSTRIAL DR
City
ITASCA
State
IL
ZIP
60143
Mailing
1500 INDUSTRIAL DR, ITASCA, IL 60143
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332510
Employees
27
Ownership type
A

5 citations on file for this inspection.

1910.107 B05 I

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Aug 17, 2023
Abate by
Sep 25, 2023
Penalty
Initial $4,687 · Current $0 Reduced
29 CFR  1910.107(b)(5)(i):The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.  On or about April 24, 2023, the average air speed over the open face of the paint spray booth was less than 100 linear feet per minute.    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.13(c).
Recent events (2)
  • — I (O) $0
  • — Z (S) $4687

1910.107 G02

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Aug 17, 2023
Abate by
Sep 25, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.107(g)(2): Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.  (A)  All spraying areas were not kept as free from the accumulation of deposits of combustible residues and/or tools used for cleaning purposes were not of nonsparking material as required.  On or about April 24, 2023, employees were exposed to fire hazards.   Spraying areas in the spray booth were not kept as free from accumulation of deposits of combustible residues, as practical, with cleaning conducted daily, if necessary.  Overspray outside the  paint booth was also found.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 17, 2023
Abate by
Nov 1, 2023
Penalty
Initial $6,250 · Current $3,750 Reduced
29 CFR  1910.151(c):Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. [63 FR 33450, June 18, 1998].  On or about August 1, 2023, employees were servicing battery-run powered industrial vehicles and were exposed to corrosive materials, such as battery acid.    There was no eyewash station in the vicinity of the charging station to quickly drench the eyes of the employees in the event of exposure to corrosive substances in the garage.  Abatement documentation is required of this item in accordance with the requirements of CFR 1903.19(d).
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6250

1910.1200 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 17, 2023
Abate by
Sep 25, 2023
Penalty
Initial $4,687 · Current $2,810 Reduced

Hazardous substances 2310

29 CFR  1910.1200(e)(1):The employer did not develop, implement and maintain at the workplace, a written hazard communication program which at least describes how the criteria specified in 29 CFR 1910.1200 (f), (g) and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met and which also includes the following:  1)  Requirement for labeling and other forms of warning;   2) Safety data sheet availability; 3)Employee information and training; 4) A list of hazardous chemicals known to be present in the  workplace; 5)Methods to inform employees of the hazards on non-routine tasks;  a. On or about April 24, 2023, the employer exposed their employees to respiratory and health hazards from chemicals such as, but not limited to, the Rust-oleum Orange Specialty Fluorescent Spray Can .The employer, United Steel & Fasteners, Inc. did not develop, implement, and maintain at the workplace a written hazard communication which at least describes how the criteria specified in 29 CFR 1910.1200(f), (g),  and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met.    b.  On or about August 1, 2023, employees were servicing battery-run powered industrial vehicles and were exposed to health hazards such as corrosive materials, specifically, battery acid/sulfuric acid.  The employer, United Steel & Fasteners, Inc. did not develop, implement, and maintain at the workplace a written hazard communication which at least describes how the criteria specified in 29 CFR 1910.1200(f), (g),  and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met.      Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2810
  • — Z (S) $4687

1910.1200 H01

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 17, 2023
Abate by
Sep 25, 2023
Penalty
Initial $0 · Current $0

Hazardous substances 2310

29 CFR  1910.1200(h)(1):Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.  a.  On or about April 24, 2023, employees were exposed to respiratory and health hazards through the use of aerosol spray cans when spray painting the switch stands specifically the orange handles.  The employees were not provided with effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced in their work areas.  b.   On or about August 1, 2023, employees were servicing battery-run powered industrial vehicles and were exposed to health hazards such as corrosive materials, specifically, battery acid/sulfuric acid.  The employees were not provided with effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced in their work areas.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View United Steel & Fasteners, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346655483.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.