Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCED OUTDOOR SOLUTIONS LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ADVANCED OUTDOOR SOLUTIONS LLC in 14990 WEST BAY RD, FAIR HAVEN, NY 13064 (NAICS 541611). OSHA activity number 346660558.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Outdoor Solutions LLC — free Get an email when a new federal OSHA severe-injury report for Advanced Outdoor Solutions LLC is published. One employer, no account, unsubscribe in one click.
Site address
14990 WEST BAY RD
City
FAIR HAVEN
State
NY
ZIP
13064
Mailing
PO BOX 344, MATLACHA, FL 33993
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541611
Employees
3
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 20, 2023
Abate by
Nov 16, 2023
Penalty
Initial $7,813 · Current $5,860 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by the load should the components of the lifting devices fail.  a) At Fair Point Marina, 14990 West Bay Rd, Fair Haven NY - Near the edge of the bay. On or about 4/26/2023, employees were using a spreader bar that was rusted and did not have the rated load capacity markings or manufacturer's markings. The spreader bar was attached below the hook of a crane and used to hoist and lower dock sections into the bay exposing employees to struck by hazards.  Among other feasible and acceptable means of abatement would be to:  1. Mark the rated load capacity on the device in accordance with the American Society of Mechanical Engineers, ASME B30.20 -2013, section 20-1.2. 2. Purchase a spreader that has the manufacturer's markings and rated load capacity on the device in accordance with the American Society of Mechanical Engineers,  ASME B30.20 -2013, section 20-1.2.
Recent events (2)
  • — I (S) $5859.75
  • — Z (S) $7813

1910.184 C14

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 20, 2023
Abate by
Nov 16, 2023
Penalty
Initial $7,813 · Current $5,860 Reduced
29 CFR  1910.184(c)(14): The employer did not ensure that sling(s) used had affixed and legible identification markings:  a) At Fair Point Marina, 14990 West Bay Rd, Fair Haven NY - Near the edge of the bay. On or about 4/26/2023, employees were hoisting and placing dock sections in the water. The steel chains and wire rope slings attached to a spreader bar, that was being used to hoist and lower dock sections, did not have affixed and legible identification markings including, but not limited to the rated load capacity markings or manufacturer's markings - exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $5859.75
  • — Z (S) $7813

1910.184 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 20, 2023
Abate by
Nov 16, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.184(e)(1): The employer did not ensure that the Alloy steel chain sling(s) used had permanently affixed durable identification stating size, grade, rated capacity, and reach:  a) At Fair Point Marina, 14990 West Bay Rd, Fair Haven NY - Near the edge of the bay. On or about 4/26/2023, employees were hoisting and placing dock sections in the water. The chains attached to a spreader bar that was being used to hoist and lower dock sections did not have permanently affixed durable identification stating size, grade, rated capacity or reach exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.184 F01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 20, 2023
Abate by
Nov 16, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.184(f)(1): The employer did not ensure that the wire rope sling(s) used had permanently affixed and legible identification markings as prescribed by the manufacturer, and did not indicate the recommended safe working load for the type(s) of hitch(es) used, the angle upon which it is based, and the number of legs if more than one.  a) At Fair Point Marina, 14990 West Bay Rd, Fair Haven NY - Near the edge of the bay. On or about 4/26/2023, employees were hoisting and placing dock sections in the water. The wire rope slings attached to a spreader bar that was being used to hoist and lower dock sections did not have permanently affixed durable identification stating size, grade, rated capacity or reach exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Advanced Outdoor Solutions LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346660558.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.