OKLAHOMA CITY, OK —
OSHA Inspection: NELSON INDUSTRIAL SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NELSON INDUSTRIAL SERVICES in 6021 MELROSE LN, OKLAHOMA CITY, OK 73127 (NAICS 238990). OSHA activity number 346662992.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NELSON INDUSTRIAL SERVICES
- Site address
- 6021 MELROSE LN
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73127
- Mailing
- 6021 MELROSE LN, OKLAHOMA CITY, OK 73127
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 40
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.253 B02 II
- Issued
- Oct 3, 2023
- Penalty
- Initial $9,376 · Current $5,625 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior: On or about April 27, 2023, the storage of cylinders and portable tanks were not stored in a proper place. This exposed employees and employees of a co-occupant of the shop to a fire hazard.
Recent events (2)
- — I (O) $5625
- — Z (S) $9376
1910.253 B02 IV
- Issued
- Oct 3, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: On or about April 27, 2023, compressed gas cylinders not in use did not have the valve protection caps in place. This exposed the employees and employees of a co-occupant of the shop to a fire hazard.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.157 C04
- Issued
- Oct 3, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not kept in their designated places when not being used: On or about April 27, 2023, a fire extinguisher was not mounted and was on the ground being used as a door stop. This exposed employees to a fire hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Nelson Industrial Services