Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MW COMPONENTS, A DIVISION OF MW INDUSTRIES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MW COMPONENTS, A DIVISION OF MW INDUSTRIES in 733 MAPLE LANE, BENSENVILLE, IL 60106 (NAICS 332722). OSHA activity number 346667744.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MW Components, a Division of MW Industries — free Get an email when a new federal OSHA severe-injury report for MW Components, a Division of MW Industries is published. One employer, no account, unsubscribe in one click.
Site address
733 MAPLE LANE
City
BENSENVILLE
State
IL
ZIP
60106
Mailing
733 MAPLE LANE, BENSENVILLE, IL 60106
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
332722
Employees
47
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2023
Abate by
Jan 31, 2024
Penalty
Initial $15,625 · Current $8,250 Reduced
29 CFR  1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:  a) On or about August 28, 2023, the employer did not ensure that employees implemented energy control application steps prior to performing setup activities on the National 316 H5 heading machine.  Hazardous energy was not isolated prior to employees engaging in servicing and maintenance activities such as machine setup.  This exposed employees to laceration and amputation hazards from unexpected movement of the machine.    As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.   Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $8250
  • — Z (S) $15625

1910.212 A01

Serious Gravity 10 2 instances 2 exposed
Issued
Sep 15, 2023
Abate by
Jan 31, 2024
Penalty
Initial $15,625 · Current $8,250 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  Examples of guarding methods are barrier guards, two-hand tripping devices, electronic safety devices, etc.  a) Production Area, Roller Department  On or about August 28, 2023 employees working on the Hartman Roller machine (R2) were exposed to amputation and crushing hazards when checking to ensure stock was forming properly by the moving die and when unjamming screws from the railing.  The employer did not adequately guard the machine to prevent employees from getting their hands / fingers caught in the moving parts of the machine.      b) Production Area, Header Department  On or about August 28, 2023 employees working on the National 316 Header machine  (H5) were exposed to ingoing nip point hazards when placing wire through the feed rollers of machine during setup and operation.  Employer did not adequately guard the feed rollers to prevent employees from getting their hands / fingers caught in the moving parts of the machine.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $8250
  • — Z (S) $15625

View MW Components, a Division of MW Industries's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346667744.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.