SAVANNAH, GA —
OSHA Inspection: JHCC HOLDINGS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JHCC HOLDINGS LLC in 3005 GIBBONS ST, SAVANNAH, GA 31404 (NAICS 811121). OSHA activity number 346671407.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JHCC HOLDINGS LLC
- Site address
- 3005 GIBBONS ST
- City
- SAVANNAH
- State
- GA
- ZIP
- 31404
- Mailing
- 1318 PIKE RD, PIKE ROAD, AL 36064
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 13
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 E01
- Issued
- Jul 13, 2023
- Penalty
- Initial $6,696 · Current $4,018 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) At JHCC Holdings LLC, located at 3005 Gibbons St, Savannah, GA 31404: on or about May 2, 2023, and at times prior to, the employer exposed employees to respiratory hazards in that the employer did not provide a medical evaluation for each employee prior to fit testing or required use of the respirator.
Recent events (2)
- — I (S) $4017.6
- — Z (S) $6696
1910.134 F02
- Issued
- Jul 13, 2023
- Abate by
- Aug 15, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) At JHCC Holdings LLC, located at 3005 Gibbons St, Savannah, GA 31404: on or about May 2, 2023, and at times prior to, the employer exposed employees to respiratory hazards in that the employer did not provide a fit test for each employee prior to use of a respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 G01 I A
- Issued
- Jul 13, 2023
- Abate by
- Aug 15, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: a) At JHCC Holdings LLC, located at 3005 Gibbons St. Savannah, GA 31404, on or about May 2, 2023, and at times prior to, the employer exposed employees to respiratory hazards in that employees wearing tight-fitting facepieces with facial hair that came between the sealing surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K
- Issued
- Jul 13, 2023
- Abate by
- Aug 15, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: a) At JHCC Holdings LLC, located at 3005 Gibbons St. Savannah, GA 31404, on or about May 2, 2023, and at times prior to, the employer exposed employees to respiratory hazards in that employees were not trained prior to required respirator use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Jul 13, 2023
- Abate by
- Aug 15, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) At JHCC Holdings LLC located at 3005 Gibbons St. Savannah, GA 31404, on or about May 2, 2023, and at times prior to, the employer exposed employees to shock hazards in that the opening for the electrical box was not kept effectively closed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Jhcc Holdings LLC