Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VERONICA ROJAS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VERONICA ROJAS in W6871 SUNNYVALE LANE, GREENVILLE, WI 54942 (NAICS 238160). OSHA activity number 346675960.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Veronica Rojas — free Get an email when a new federal OSHA severe-injury report for Veronica Rojas is published. One employer, no account, unsubscribe in one click.
Establishment
VERONICA ROJAS
Site address
W6871 SUNNYVALE LANE
City
GREENVILLE
State
WI
ZIP
54942
Mailing
1569 MALOA STREET, MENASHA, WI 54952
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 7 exposed
Issued
May 5, 2023
Penalty
Initial $3,349 · Current $2,009 Reduced
29 CFR  1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  On or about May 4, 2023, at an establishment located at W6871 Sunnyvale Lane in Greenville, Wisconsin, employees of Wolfe Consulting were performing residential roofing activities with no form of conventional fall protection while exposed to fall hazards of over 17 feet.
Recent events (2)
  • — I (S) $2009.4
  • — Z (S) $3349

1926.1053 B01

Serious Gravity 10 1 instance 7 exposed
Issued
May 5, 2023
Penalty
Initial $4,688 · Current $2,813 Reduced
29 CFR  1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  On or about May 4, 2023, at an establishment located at W6871 Sunnyvale Lane in Greenville, Wisconsin, employees of Wolfe Consulting were utilizing a ladder for access and egress to the roof of residential construction townhomes that did not have side rails extended 3 feet above the upper landing surface exposing employees to fall hazards of over 10 feet.
Recent events (2)
  • — I (S) $2812.6
  • — Z (S) $4688

1926.1053 B05 I

Serious Gravity 5 1 instance 5 exposed
Issued
May 5, 2023
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(5)(i): Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).  On or about May 4, 2023, at an establishment located at W6871 Sunnyvale Lane in Greenville, Wisconsin, employees of Wolfe Consulting were utilizing a ladder for access and egress to the upper roof section of residential construction townhomes that was not at an angle of one quarter the working length of the ladder exposing employees to fall hazards of approximately 6 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Veronica Rojas's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346675960.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.