Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE METAL SHOP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THE METAL SHOP in 8409 W CRYSTAL ST, CRYSTAL RIVER, FL 34428 (NAICS 333415). OSHA activity number 346679798.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Metal Shop — free Get an email when a new federal OSHA severe-injury report for The Metal Shop is published. One employer, no account, unsubscribe in one click.
Establishment
THE METAL SHOP
Site address
8409 W CRYSTAL ST
City
CRYSTAL RIVER
State
FL
ZIP
34428
Mailing
2541 W DUNNELLON RD, DUNNELLON, FL 34433
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
20
Ownership type
A

8 citations on file for this inspection.

1910.36 D01

Serious Gravity 1 3 instances 9 exposed
Issued
Oct 13, 2023
Abate by
Nov 2, 2023
Penalty
Initial $4,687 · Current $2,812 Reduced
29 CFR 1910.36(d)(1):  Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  a)  Duct Board Fabrication - On or about May 03, 2023, employees were exposed to entrapment and fire hazards in that, all exit doors were equipped with panic bars, sliding bolt locks and door levers with twist knob locks.
Recent events (2)
  • — I (S) $2812
  • — Z (S) $4687

1910.37 A03

Serious Gravity 1 2 instances 9 exposed
Issued
Oct 13, 2023
Abate by
Oct 25, 2023
Penalty
Initial $4,687 · Current $2,812 Reduced
29 CFR 1910.37(a)(3):  Exit route(s) were not kept free and unobstructed:  a)  Duct Board Fabrication - On or about May 03, 2023, the employer exposed employees to fire and entrapment hazards caused from stacked wooden pallets stored outside of exit discharge.  b) Center of Warehouse for finished Duct Board exit door - On or about May 03, 2023, the employer exposed employees to fire and entrapment hazards caused from stacked processed duct board and broken-down cardboard boxes were stored in the exit path.
Recent events (2)
  • — I (S) $2812.4
  • — Z (S) $4687

1910.212 A01

Serious Gravity 5 2 instances 1 exposed
Issued
Oct 13, 2023
Abate by
Oct 25, 2023
Penalty
Initial $6,250 · Current $3,750 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Metal Shop - On or about May 03, 2023, the employer exposed employees to metal flying chips and/or lacerations while operating a milling machine to drill holes into metal.  b) Metal Shop - On or about May 03, 2023, the employer exposed employees to metal flying chips and/or lacerations while cutting metal legs with a Lockformer Saw.
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6250

1910.134 C02 I

Other-than-serious 2 instances 2 exposed
Issued
Oct 13, 2023
Abate by
Nov 2, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a)  Metal Shop, Paint, Duct Board Fabrication - On or about May 03, 2023, the employer exposed employees to injuries while offering disposable N95 respirators for voluntary use.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 II

Other-than-serious 1 instance 5 exposed
Issued
Oct 13, 2023
Abate by
Nov 2, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: (Construction Reference 1926.103)  (a)  Metal Shop, Welding, Paint and Duct Board Fabrication - On or about May 05, 2023, the employer exposed employees to injuries while providing 3M Half Mask Respirators with filtering cartridges voluntarily upon request without creating a written program with necessary elements.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Oct 13, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Duct Board Fabrication - On or about May 03, 2023, the employer exposed employees to minor burns and/or electrical shock in that, the employer did not ensure that electrical equipment  was used or installed in accordance with manufacturer instructions.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 8 exposed
Issued
Oct 13, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Metal Shop and Duct Board Fabrication - On or about May 05, 2023, the employer exposed employees to minor burns and/or electrical shock while using flexible cords hung and mounted to power overhead lighting and machinery throughout the facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 2 exposed
Issued
Oct 13, 2023
Abate by
Oct 25, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(2)(iii):Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a)  Metal Shop - On or about May 05, 2023, the employer exposed employees to minor burns and/or electrical shock while using a flexible cord with missing strain relief to provide power to a floor fan.  b)  Metal Shop - On or about May 05, 2023, the employer exposed employees to minor burns and/or electrical shock while using a flexible cord with missing strain relief to provide power to the Lockformer Saw.  c)  Welding area - On or about May 05, 2023, the employer exposed employees to minor burns and/or electrical shock while using a flexible cord with missing strain relief to provide power to hand tools.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View The Metal Shop's full OSHA safety record →