HIGH SPRINGS, FL —
OSHA Inspection: AIR LIQUIDE ADVANCED MATERIALS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AIR LIQUIDE ADVANCED MATERIALS, INC. in 17526 HIGH SPRINGS MAIN STREET, HIGH SPRINGS, FL 32643 (NAICS 325120). OSHA activity number 346682131.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AIR LIQUIDE ADVANCED MATERIALS, INC.
- Site address
- 17526 HIGH SPRINGS MAIN STREET
- City
- HIGH SPRINGS
- State
- FL
- ZIP
- 32643
- Mailing
- 17526 HIGH SPRINGS MAIN STREET, HIGH SPRINGS, FL 32643
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325120
- Employees
- 77
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.119 D01 VI
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(d)(1)(vi): Process safety information (PSI) pertaining to the hazards of the highly hazardous chemicals in the process did not contain thermal and chemical stability data of the chemicals used in the process: a) For the facility located at 17526 High Springs Main Street, High Springs, Florida: On or about May 4, 2023, process safety information for the processes of synthesizing, purification, transfilling(mixing), etc. of Diborane and its mixtures did not contain information on the thermal degradation and reactivity of the product during the manufacturing. The facility failed to stipulate temperature limits for the aluminum vessels and for the chemical(s) inside the vessels. Employees working on and in the vicinity of equipment containing highly hazardous chemicals were exposed to fire, explosion, respiratory and contact hazards.
Recent events (3)
- — F (S) $0
- — C (S) $10938
- — Z (S) $10938
1910.119 D02 I D
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $0 · Current $8,203
General-duty citation text
29 CFR 1910.119(d)(2)(i)(D): Process safety information pertaining to the technology of the process did not include the safe upper and lower limits for such items as temperatures, pressures, flows or compositions: a) For the facility located at 17526 High Springs Main Street, High Springs, Florida: On or about May 4, 2023, process safety information was incomplete; in that the documents provided did not properly include safe upper and lower limits for temperatures concerning vessels used in the process of synthesizing, purification, transfilling(mixing), etc. of Diborane and its mixtures. The facility failed to stipulate temperature limits for the aluminum vessels and for the chemical(s) inside the vessel. Employees working on and in the vicinity of equipment containing highly hazardous chemicals were exposed to fire, explosion, respiratory and contact hazards.
Recent events (3)
- — F (S) $8203
- — C (S) $0
- — Z (S) $0
1910.119 D02 I E
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(d)(2)(i)(E): Information concerning the technology of the process did not include an evaluation of the consequences of deviations, including those affecting the safety and health of employees: a) For the facility located at 17526 High Springs Main Street, High Springs, Florida: On or about May 4, 2023, information concerning the technology of the process system information required in the process the employer failed to include an evaluation of consequences of exceeding temperature limits for the vessels and the chemical(s) within them as required for the processes using diborane. Failure to accurately establish safe operating limits for process involved in the production of diborane and evaluating consequences of exceeding limits led to the employees working on and in the vicinity of the highly hazardous chemical being exposed to fire, explosion, respiratory and contact hazards.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.119 E03 I
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $10,938 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(i): The process hazard analysis did not address the hazards of the process: a) For the facility located at 17526 High Springs Main Street, High Springs, Florida: On or about May 4, 2023, the employer did not conduct a PHA that adequately addressed the issue of the hazards related to impure or contaminated materials that may be produced in mixing and reaction processes. Activities concerning vessels used in the process of synthesizing, purification, transfilling(mixing), etc. of Diborane and its mixtures may produce by-products that affect the stability of vessels when heated. Employees working on and in the vicinity of equipment containing highly hazardous chemicals are exposed to fire, explosion, respiratory and contact hazards.
Recent events (3)
- — F (O) $7000
- — C (S) $10938
- — Z (S) $10938
1910.119 E05
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $10,938 · Current $8,203 Reduced
General-duty citation text
29 CFR 1910.119(e)(5): The employer shall establish a system to promptly address the team's findings and recommendations; assure that the recommendations are resolved in a timely manner and that the resolution is documented; document what actions are to be taken; complete actions as soon as possible; develop a written schedule of when these actions are to be completed; communicate the actions to operating, maintenance and other employees whose work assignments are in the process and who may be affected by the recommendations or actions. a) For the facility located at 17526 High Springs Main Street, High Springs, Florida: On or about May 4, 2023, the employer failed to promptly address Process Hazard Analysis recommendations with respect to heating the cylinders in the diborane process, track resolutions of such recommendations as soon as possible and communicate the actions to operating employees who may be affected by the recommendations or actions. Employees working on and in the vicinity of equipment containing highly hazardous chemicals were exposed to fire, explosion, respiratory and contact hazards.
Recent events (3)
- — F (S) $8203
- — C (S) $10938
- — Z (S) $10938
1910.119 E07
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(e)(7): Employers shall retain process hazards analyses and updates or revalidations for each process covered by this section, as well as the documented resolution of recommendations described in paragraph (e)(5) of this section for the life of the process. a) For the facility located at 17526 High Springs Main Street, High Springs, Florida: On or about May 4, 2023, the employer failed to retain and address Process Hazard Analysis recommendations with respect to heating the cylinders in the diborane process and track resolutions of such recommendations.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.119 F01 II
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $10,938 · Current $8,203 Reduced
General-duty citation text
29 CFR 1910.119(f)(1)(ii): The employer's written operating procedures did not address the requirements for the operating limits related to temperatures of cylinders: a) For the facility located at 17526 High Springs Main Street, High Springs, Florida: On or about May 4, 2023, the employer's written operating procedures were incomplete; in that the documents provided did not properly include safe instructions for chemical transfer activities concerning vessel exposure to heat before, during and after the process of synthesizing, purification, transfilling(mixing), etc. of Diborane and its mixtures. Employees working on and in the vicinity of equipment containing highly hazardous chemicals were exposed to fire, explosion, respiratory and contact hazards.
Recent events (3)
- — F (S) $8203
- — C (S) $10938
- — Z (S) $10938
1910.119 J06 II
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $10,938 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.119(j)(6)(ii): Appropriate checks and inspections shall be performed to assure that equipment is installed properly and consistent with design specifications and the manufacturer?s instructions. a) For the facility located at 17526 High Springs Main Street, High Springs, Florida: On or about May 4, 2023, the employer exposed employees to fire and explosion hazards in that the employer failed to require and complete inspections and checks to assure design and manufacturer?s specifications are met with equipment such as, but not limited to, non-rated electrical equipment used in the process of synthesizing, purification, transfilling (mixing), etc. of Diborane and its mixtures.
Recent events (3)
- — F (S) $6000
- — C (S) $10938
- — Z (S) $10938
1910.307 C02 I
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $10,938 · Current $10,938
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment in hazardous (classified) location(s) was not approved for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that was or could be present: a) On or about May 4, 2023, within the H-Space building number 3 in the Synthesis 1 Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use improperly rated equipment such as, but not limited to vacuum pumps within a Class I Division II Group B manifold/hood while synthesizing a flammable chemical. b) On or about May 4, 2023, within the H-Space building number 3 in the Synthesis 2 Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use improperly rated equipment such as, but not limited to vacuum pumps within a Class I Division II Group B manifold/hood while synthesizing a flammable chemical. c) On or about May 4, 2023, within the H-Space building number 3 in the Mixing 1 Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use improperly rated equipment such as, but not limited to vacuum pumps within a Class I Division II Group B manifold/hood while mixing/transfilling a flammable chemical. d) On or about May 4, 2023, within the H-Space building number 3 in the Mixing 2 Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use improperly rated equipment such as, but not limited to vacuum pumps within a Class I Division II Group B manifold/hood while mixing/transfilling a flammable chemical. e) On or about May 4, 2023, within the H-Space building number 3 in the Mixing 3 Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use improperly rated equipment such as, but not limited to vacuum pumps within a Class I Division II Group B manifold/hood while mixing/transfilling a flammable chemical. f) On or about May 4, 2023, within the H-Space building number 3 in the Purification Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use improperly rated equipment such as, but not limited to vacuum pumps within a Class I Division II Group B manifold/hood while purifying/distilling a flammable chemical. g) On or about May 4, 2023, within the H-Space building number 3 in the Cryotrap Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use improperly rated equipment such as, but not limited to vacuum pumps within a Class I Division II Group B manifold/hood while cryotrapping a flammable chemical. h) On or about May 4, 2023, within the H-Space building number 3 in the Quality Control Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use improperly rated equipment such as, but not limited to vacuum pumps within a Class I Division II Group B manifold/hood while checking quality of the products of a flammable chemical.
Recent events (3)
- — F (S) $10938
- — C (S) $10938
- — Z (S) $10938
1910.307 G02 II
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $10,938 · Current $0 Reduced
General-duty citation text
29 CFR 1910.307(g)(2)(ii): Each room, section, or area was not considered individually in determining its classification. a) For the facility located at 17526 High Springs Main Street, High Springs, Florida: On or about May 4, 2023, the employer exposed employees to fire, explosion, respiratory and contact hazards, in that the H-Space or Building 3 was not electrically classified properly as a Class I Division II environment where diborane would become hazardous in case of an accident or some unusual operating condition.
Recent events (3)
- — F (S) $0
- — C (S) $10938
- — Z (S) $10938
1910.119 D03 I C
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(d)(3)(i)(C): Electrical classification; In instances of areas within the same facility classified separately, Class I, Zone 2 locations may abut, but not overlap, Class I, Division 2 locations. Class I, Zone 0 or Zone 1 locations may not abut Class I, Division 1 or Division 2 locations. a) For the facility located at 17526 High Springs Main Street, High Springs, Florida: On or about May 4, 2023, the employer exposed employees to fire, explosion, respiratory and contact hazards, in that the H-Space or Building 3 was not electrically classified properly as a Class I Division II environment where diborane would become hazardous in case of an accident or some unusual operating condition.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.119 D03 II
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $0 · Current $10,938
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. a) For the facility located at 17526 High Springs Main Street, High Springs, Florida: On or about May 4, 2023, the employer exposed employees to fire, contact and explosion hazards in that the employer required and failed to document that equipment such as, but not limited to, heat guns used in the process of synthesizing, purification, transfilling(mixing), etc. of Diborane and its mixtures complied with recognized and generally accepted good engineering practices as identified in the equipment's manufacturer's manual.
Recent events (3)
- — F (S) $10938
- — C (S) $0
- — Z (S) $0
1910.307 C
- Issued
- Nov 3, 2023
- Abate by
- Dec 1, 2023
- Penalty
- Initial $125,007 · Current $75,000 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: a) On or about May 4, 2023, within the H-Space building number 3 in the Synthesis 1 Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use equipment such as, but not limited to, heat guns that were not intrinsically safe or designed to be used within a Class I Division II Group B manifold/hood where flammable chemicals and vapors are present while synthesizing Diborane. b) On or about May 4, 2023, within the H-Space building number 3 in the Synthesis 2 Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use equipment such as, but not limited to, heat guns that were not intrinsically safe or designed to be used within a Class I Division II Group B manifold/hood where flammable chemicals and vapors are present while synthesizing Diborane. c) On or about May 4, 2023, within the H-Space building number 3 in the Mixing 1 Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use equipment such as, but not limited to, heat guns that were not intrinsically safe or designed to be used within a Class I Division II Group B manifold/hood where flammable chemicals and vapors are present while mixing/transfilling Diborane and its mixtures. d) On or about May 4, 2023, within the H-Space building number 3 in the Mixing 2 Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use equipment such as, but not limited to, heat guns that were not intrinsically safe or designed to be used within a Class I Division II Group B manifold/hood where flammable chemicals and vapors are present while mixing/transfilling Diborane and its mixtures. e) On or about May 4, 2023, within the H-Space building number 3 in the Mixing 3 Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use equipment such as, but not limited to, heat guns that were not intrinsically safe or designed to be used within a Class I Division II Group B manifold/hood where flammable chemicals and vapors are present while mixing/transfilling Diborane and its mixtures. f) On or about May 4, 2023, within the H-Space building number 3 in the Purification Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use equipment such as, but not limited to, heat guns that were not intrinsically safe or designed to be used within a Class I Division II Group B manifold/hood where flammable chemicals and vapors are present while purifying/distilling Diborane. g) On or about May 4, 2023, within the H-Space building number 3 in the Cryotrap Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use equipment such as, but not limited to, heat guns that were not intrinsically safe or designed to be used within a Class I Division II Group B manifold/hood where flammable chemicals and vapors are present while cryotrapping flammable chemicals. h) On or about May 4, 2023, within the H-Space building number 3 in the Quality Control Hood/Manifold, the employer exposed employees to fire and explosion hazards in that the employer required employees to use equipment such as, but not limited to, heat guns that were not intrinsically safe or designed to be used within a Class I Division II Group B manifold/hood where flammable chemicals and vapors are present while checking quality of flammable chemicals.
Recent events (3)
- — F (S) $75000
- — C (W) $125007
- — Z (W) $125007
More inspections at AIR Liquide Advanced Materials, INC.
View AIR Liquide Advanced Materials, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325120)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346682131.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.