ODESSA, TX —
OSHA Inspection: WELL SERVICE PARTNERS, LLC
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of WELL SERVICE PARTNERS, LLC in 3945 WEST 42ND STREET, ODESSA, TX 79764 (NAICS 213112). OSHA activity number 346683410.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WELL SERVICE PARTNERS, LLC
- Site address
- 3945 WEST 42ND STREET
- City
- ODESSA
- State
- TX
- ZIP
- 79764
- Mailing
- 1310 MCCRAE TRAIL, SOUTHLAKE, TX 76092
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 10
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.151 C
- Issued
- Sep 20, 2023
- Abate by
- Oct 19, 2023
- Penalty
- Initial $3,572 · Current $2,143 Reduced
General-duty citation text
29 CFR 1910.151(c):Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. [63 FR 33450, June 18, 1998] On or about May 2, 2023, the employer failed to ensure that a suitable eyewash station was provided in the shop area exposing employees to injurious eye hazards. There was not other eye wash station nearby and the eye wash bottles were expired.
Recent events (2)
- — I (S) $2143.2
- — Z (S) $3572
1910.178 P01
- Issued
- Sep 20, 2023
- Abate by
- Oct 19, 2023
- Penalty
- Initial $5,358 · Current $3,215 Reduced
General-duty citation text
29 CFR 1910.178(p)(1):If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition. On or about May 2, 2023, employees exposed to struck by hazards, because employer allowed the employees to use the the Forklift caterpillar TH62 that was defective
Recent events (2)
- — I (S) $3214.8
- — Z (S) $5358
1910.179 J02 III
- Issued
- Sep 20, 2023
- Abate by
- Oct 19, 2023
- Penalty
- Initial $5,358 · Current $3,215 Reduced
General-duty citation text
29 CFR 1910.179(j)(2)(iii):Hooks with deformation or cracks. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected. For hooks with cracks or having more than 15 percent in excess of normal throat opening or more than 10�� twist from the plane of the unbent hook refer to paragraph (l)(3)(iii)(a) of this section. On or about May 2, 2023, the employer did not conducted monthly inspection on the crane hooks (crane S/N-30510M002) and the employees were lifting equipment included but not limited to BOP's.
Recent events (2)
- — I (S) $3214.8
- — Z (S) $5358
1910.253 B02 IV
- Issued
- Sep 20, 2023
- Abate by
- Oct 19, 2023
- Penalty
- Initial $3,572 · Current $2,143 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv):Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use. On or about May 2, 2023, an oxy-acetylene torch sets were stored on a welding cart without the cylinder caps installed.
Recent events (2)
- — I (S) $2143.2
- — Z (S) $3572
1910.303 G01 II
- Issued
- Sep 20, 2023
- Abate by
- Oct 19, 2023
- Penalty
- Initial $2,678 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded. On or about May 2, 2023 employer did not make sure to have sufficient working space about the electrical panel.
Recent events (2)
- — I (S) $1606.8
- — Z (S) $2678
1910.178 L
- Issued
- Sep 20, 2023
- Abate by
- Oct 19, 2023
- Penalty
- Initial $7,143 · Current $4,286 Reduced
General-duty citation text
29 CFR 1910.178(l):Operators were not trained in the safe operation of powered industrial trucks On or about May 2, 2023, the employer did not ensure forklift operators were trained to operate the forklifts, and failed to train operators after being cited in a pervious inspection as abatement The Well Service Partners, LLC DBA Yellowcat Fishing & Rental, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.178(l), which was contained in OSHA inspection number1577088, citation number 1, item number 1 and was affirmed as a final order on 05-11-2022, with respect to a workplace located at 3945 West 42nd Street Odessa TX 79764.
Recent events (2)
- — I (R) $4285.8
- — Z (R) $7143
1910.178 Q07
- Issued
- Sep 20, 2023
- Abate by
- Oct 19, 2023
- Penalty
- Initial $7,143 · Current $4,286 Reduced
General-duty citation text
29 CFR 1910.178(q)(7):Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected. On or about May 2, 2023, the employer failed to ensure forklift were inspected prior to being placed in service after being cited in a pervious inspection as abatement The Well Service Partners, LLC DBA Yellowcat Fishing & Rental, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.178(l), which was contained in OSHA inspection number1577088, citation number 1, item number 1 and was affirmed as a final order on 05-11-2022, with respect to a workplace located at 3945 West 42nd Street Odessa TX 79764.
Recent events (2)
- — I (R) $4285.8
- — Z (R) $7143
1910.303 B01 VII
- Issued
- Sep 20, 2023
- Abate by
- Oct 19, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1)(vii):Classification by type, size, voltage, current capacity, and specific use; and On or about May 2, 2023, employer did not mark the electrical boxes as required to indicate voltage, current, wattage, or other ratings as necessary
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Well Service Partners, LLC
View Well Service Partners, LLC's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346683410.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.