MINEOLA, NY ·
OSHA Inspection: SEARING GROUP LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SEARING GROUP LLC in 101 SEARING AVE, MINEOLA, NY 11501 (NAICS 236116). OSHA activity number 346686355.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEARING GROUP LLC
- Site address
- 101 SEARING AVE
- City
- MINEOLA
- State
- NY
- ZIP
- 11501
- Mailing
- 136 WILLIS AVENUE, MINEOLA, NY 11501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 10
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.651 J02
- Issued
- Oct 3, 2023
- Abate by
- Oct 10, 2023
- Penalty
- Initial $3,349 · Current $3,349
General-duty citation text
29 CFR 1926.651(j)(2):Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of the excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) At the Worksite 101 Searing Ave Mineola NY. On or about May 8th, 2023 , Spoil piles, were placed directly on the edge of the excavation. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (3)
- · R (O) $3349
- · C (S) $3349
- · Z (S) $3349
1926.652 A01
- Issued
- Oct 3, 2023
- Abate by
- Oct 10, 2023
- Penalty
- Initial $4,688 · Current $4,688
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): a) Worksite South side 101 Searing Avenue Mineola NY. On or about May 8th, 2023 Employees were installing concrete forms in an excavation approximately 10 feet deep. The excavation had vertical walls and the employees were not protected from cave-ins by and adequate protective system. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (3)
- · R (O) $4688
- · C (S) $4688
- · Z (S) $4688
More inspections in this industry (NAICS 236116)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 346686355.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.