Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EL PASO STEEL DOORS & FRAMES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EL PASO STEEL DOORS & FRAMES in 4121 N PIEDRAS ST., EL PASO, TX 79930 (NAICS 444190). OSHA activity number 346693815.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch EL Paso Steel Doors & Frames — free Get an email when a new federal OSHA severe-injury report for EL Paso Steel Doors & Frames is published. One employer, no account, unsubscribe in one click.
Site address
4121 N PIEDRAS ST.
City
EL PASO
State
TX
ZIP
79930
Mailing
4121 N PIEDRAS ST., EL PASO, TX 79930
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444190
Employees
10
Ownership type
A

6 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 15, 2023
Abate by
Oct 16, 2023
Penalty
Initial $4,018 · Current $2,400 Reduced
29 CFR  1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).  On or about May 8, 2023, employer did not ensure that employees operating the forklift were trained and certified to operate the forklift. This condition exposed employees to struck-by hazards.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4018

1910.243 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 15, 2023
Abate by
Oct 16, 2023
Penalty
Initial $4,018 · Current $2,000 Reduced
29 CFR  1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4)(a).  On or about May 8, 2023, employer did not ensure to install guards to hand held grinders. This condition exposed employees to amputation hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4018

1910.305 B01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 15, 2023
Abate by
Oct 16, 2023
Penalty
Initial $2,009 · Current $1,200 Reduced
29 CFR  1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.  On or about May 8, 2023, employer did not ensure to cover several knock out openings in the electrical box.  This condition exposed employees to electrical hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2009

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 15, 2023
Abate by
Oct 16, 2023
Penalty
Initial $2,009 · Current $1,200 Reduced
29 CFR  1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.  On or about May 8, 2023, employer did not ensure to provide covers to the following Items:  a) Electrical switch at the 45 degree cutting machine.  b) Electrical outlet feeding the 45 degree cutting machine.   These conditions exposed employees to electrical hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2009

1910.305 G02 III

Serious Gravity 1 3 instances 2 exposed
Issued
Sep 15, 2023
Abate by
Oct 16, 2023
Penalty
Initial $2,009 · Current $1,200 Reduced
29 CFR  1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  On or about May 8, 2023, employer did not ensure to install strain relief components to cables in the following instances:   a) At the extension cord feeding the router power tool. b) In the electrical box feeding the Wilson 45 degree saw.  C. At the  Wilson 45 degree saw connection.  These conditions exposed employees to electrical hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2009

1910.334 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 15, 2023
Abate by
Oct 16, 2023
Penalty
Initial $3,349 · Current $2,000 Reduced
29 CFR  1910.334(a)(3)(ii): Attachment plugs and receptacles may not be connected or altered in a manner which would prevent proper continuity of the equipment grounding conductor at the point where plugs are attached to receptacles. Additionally, these devices may not be altered to allow the grounding pole of a plug to be inserted into slots intended for connection to the current-carrying conductors.  On or about May 8, 2023, employer used an extension cord that was missing the ground prone connector. This condition exposed employees to electrical hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3349

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346693815.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.