Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALBRIGHTSON EXCAVATING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALBRIGHTSON EXCAVATING, INC. in 3655 SCHNEIDER AVENUE, MENOMONIE, WI 54751 (NAICS 238910). OSHA activity number 346697873.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Albrightson Excavating, INC. — free Get an email when a new federal OSHA severe-injury report for Albrightson Excavating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3655 SCHNEIDER AVENUE
City
MENOMONIE
State
WI
ZIP
54751
Mailing
PO BOX 181, WOODVILLE, WI 54028
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.600 A06 I

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 21, 2023
Abate by
Sep 12, 2023
Penalty
Initial $7,306 · Current $6,000 Reduced
29 CFR 1926.600(a)(6)(i): For lines rated 50kV or below, a minimum of 10 feet was not maintained between the energized line and the equipment:  (a) South side of excavation; A Komatsu model PC490LC-11 excavator was being operated to backfill an excavation when the arm and/or boom of the excavator struck and broke the neutral wire of an energized overhead 3-phase, 7200-volt transmission line.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $7306

1926.600 A06 IV

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Aug 21, 2023
Abate by
Sep 12, 2023
Penalty
Initial $7,306 · Current $0 Reduced
29 CFR 1926.600(a)(6)(iv): A person was not designated to observe clearance of the equipment and give timely warning for all operations where it is difficult for the operator to maintain the desired clearance by visual means:  (a) South side of excavation; A designated spotter/ signal person was not provided and used to warn the excavator operator of hazards presented by overhead electrical hazards while the excavator was being operated in the vicinity of and within the minimum approach boundary of an energized 3-phase, 7200-volt transmission line.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7306