WASHINGTON, DC —
OSHA Inspection: MOTIVATE LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MOTIVATE LLC in 6035 BLAIR ROAD NW, WASHINGTON, DC 20011 (NAICS 532284). OSHA activity number 346708902.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOTIVATE LLC
- Site address
- 6035 BLAIR ROAD NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20011
- Mailing
- 6035 BLAIR ROAD NW, WASHINGTON, DC 20011
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 532284
- Employees
- 74
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 27, 2023
- Abate by
- Nov 6, 2023
- Penalty
- Initial $14,063 · Current $14,063
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm from crushing hazards to employees due to collapse or tip-over of a storage rack system. (a) Warehouse: On or about May 17, 2023, an employee loading and unloading batteries for electric bikes from a storage rack system used for charging was exposed to crushing hazards from a collapse or tip-over of the approximate 742.5 pound storage rack system due to unanchored rack columns that affected the stability. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records. Abatement Note: Among other methods, feasible and acceptable abatement methods to correct this hazard are to follow American National Standard Institute (ANSI) and Rack Manufacturers Institute (RMI)-ANSI-RMI MH 16:1-2012, "Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks." Under paragraph 1.4.7 Column Base Plates and Anchors: "The bottom of all columns shall be furnished with column base plates, as specified in 7.1. All rack columns shall be anchored to the floor with anchor bolts, which shall be designed in accordance with Section 7.3, to resist all applicable forces as described in Section 2.1 or Section 2.2."
Recent events (3)
- — F (S) $14063
- — C (S) $14063
- — Z (S) $14063
1910.304 B04 II B
- Issued
- Oct 27, 2023
- Abate by
- Nov 6, 2023
- Penalty
- Initial $8,539 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4: (a) Warehouse Battery Charging Area: On or about July 11, 2023, an employee was exposed to an electrically overloaded Tripp Lite relocatable (RLT) power tap. The maximum intended load was exceeded for both the RLT and the electrical outlet when the RLT was rated for 20 amps but was powering 10 Watson battery chargers pulling a total amperage of 25 amps, and that was powered by an outlet rated for a total maximum intended load of 12 amps. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $0
- — C (S) $8539
- — Z (S) $8539
1910.136 A
- Issued
- Oct 27, 2023
- Abate by
- Nov 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.136(a): The employer did not assure that each affected employee used protective footwear when working in areas where there was a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet were exposed to electrical hazards. (a) Warehouse: On or about May 17, 2023, employees were exposed to foot injuries when loading and unloading batteries weighing up to 16.5 pounds as a result of not being provided with protective footwear. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Oct 27, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries. (a) Warehouse, Bike Shop: On or about May 17, 2023, employees performing maintenance work on electric bikes were exposed to two unmounted and one partially blocked fire extinguisher in the bike shop. No abatement certification or documentation required for this item.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Oct 27, 2023
- Abate by
- Nov 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. (a) Warehouse: On or about July 11, 2023, an employee loading and unloading batteries from their respective chargers was exposed to two daisy chained 25-foot 12 AWG Well Shin 3 x 3.31mm extension cords that powered the chargers. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.304 G05
- Issued
- Oct 27, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. (a) Warehouse: On or about July 11, 2023, an employee working on a work bench in the warehouse used a 120 volt portable lamp for lighting that did not have the grounding prong installed on the plug. No abatement certification or documentation required for this item.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Motivate LLC
View Motivate LLC's full OSHA safety record →
More inspections in this industry (NAICS 532284)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346708902.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.