Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAYANCELA REMODELLING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MAYANCELA REMODELLING in 8040 ROLL ROAD, EAST AMHERST, NY 14051 (NAICS 238160). OSHA activity number 346713050.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mayancela Remodelling — free Get an email when a new federal OSHA severe-injury report for Mayancela Remodelling is published. One employer, no account, unsubscribe in one click.
Site address
8040 ROLL ROAD
City
EAST AMHERST
State
NY
ZIP
14051
Mailing
6 WALNUT PLACE, SPRING VALLEY, NY 10977
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
14
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 1 1 instance 14 exposed
Issued
Jul 20, 2023
Penalty
Initial $1,935 · Current $1,935
29 CFR  1926.501(b)(11):Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a) On or about 5/16/2023, at the roof area of the site, East Amherst, NY. Employees, engaged in roofing work of 5 in 12 main roof and 7 in 12 peaks, were not protected by fall protections.   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $1935

1926.1053 B01

Serious Gravity 1 1 instance 14 exposed
Issued
Jul 20, 2023
Penalty
Initial $1,935 · Current $1,935
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On or about 5/16/2023, at the roof area of the site, East Amherst, NY. Employees, engaged in tearing and installing roof shingles on 5 in 12 and 7 in 12 roofs, used extension ladders to access the roof, and the ladder side rails did not extend at least 3 feet above the upper landing.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $1935

View Mayancela Remodelling's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346713050.