Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARMY JOINT BASE GARRISON - DIRECTORATE OF PUBLIC WORKS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ARMY JOINT BASE GARRISON - DIRECTORATE OF PUBLIC WORKS in 2012 LIGGETT AVE., JOINT BASE LEWIS MCCHORD, WA 98433 (NAICS 928110). OSHA activity number 346714058.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Army Joint Base Garrison - Directorate of Public Works — free Get an email when a new federal OSHA severe-injury report for Army Joint Base Garrison - Directorate of Public Works is published. One employer, no account, unsubscribe in one click.
Site address
2012 LIGGETT AVE.
City
JOINT BASE LEWIS MCCHORD
State
WA
ZIP
98433
Mailing
BLDG 2007A N. 2ND ST MS-66 BOX 339500, JOINT BASE LEWIS MCCHORD, WA 98433
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
316
Ownership type
D

5 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 7, 2023
Abate by
Sep 22, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling:  A) The catwalk system in the McChord Boiler Plant had several walkways that were open sided. Employees working on boilers from the walkways on the catwalk system with no fall protection were exposed to fall hazards of 15 to 40 foot heights.
Recent events (1)
  • — Z (S) $0

1910.107 G02

Serious Gravity 1 2 instances 3 exposed
Issued
Aug 7, 2023
Abate by
Sep 22, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.107(g)(2): Cleaning. All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:  A)     In the Paint shop, there was a spray booth with accumulations of paint residue/overspray that created a rough surface over the walls of the booth.  B)     In the Structures shop, there was a small open-faced spray booth with accumulations of paint residue/overspray that created a rough surface over the walls and work surface of the booth.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 7, 2023
Abate by
Sep 22, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.215(a)(4): Work rests. On offhand grinding machines, work rests shall be used to support the work.  Work rests were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage:  A)     In the HVAC shop, there was a Promax bench grinder that had its work rest adjusted to one-quarter inch from the surface of the grinding wheel.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 7, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel.  The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch:  A)      In the Welding shop, there was a bench grinder where the tongue guard was not properly adjusted.  The guard was seven-eighth inch from the surface of the grinding wheel.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 7, 2023
Abate by
Sep 22, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:  A)     In the HVAC shop there was an energized wall mounted junction box that had several openings that were not closed.